Diagnostic accuracy of molecular and non-molecular assays for urogenital schistosomiasis in Zambian schoolchildren: a latent class and composite reference standard analysis

Background Diagnosis of urogenital schistosomiasis is hampered by the lack of a true gold standard, as urine microscopy misses light and early infections. This study aimed to compare the diagnostic performance of molecular and non-molecular assays for urogenital schistosomiasis using different reference standards. Methods We evaluated three molecular assays (Dra1 qPCR, a species-specific LAMP for Schistosoma haematobium [Sh-LAMP] and a genus-specific Schistosoma LAMP) alongside urine microscopy, dipstick microhaematuria and a Sh -TSP-2 ELISA in 89 urine samples from schoolchildren in Lusaka Province, Zambia. Performance was assessed against microscopy, latent class analysis (LCA) and a composite reference standard (CRS). Sensitivity, specificity, likelihood ratios, predictive values and overall accuracy were calculated, and pairwise agreement between tests was assessed by correlation analysis. Results Microscopy identified 31 infected children (34.8%; 95% CI 25.0–45.7), compared with 35 (39.3%; 95% CI 29.1–50.3) by LCA and 55 (61.8%; 95% CI 50.9–71.9) by CRS. qPCR had the highest sensitivity in all three analyses (96.4–100%). Sh-LAMP was less sensitive than qPCR, with sensitivities of 87.1%, 85.7%, and 87.3% against microscopy, LCA, and the CRS, respectively. However, it achieved the highest overall accuracy of the molecular assays against microscopy and the CRS (58.4% and 78.7%, respectively). Microscopy and microhaematuria were fully specific under LCA and CRS, although their sensitivity against the CRS was only 56.4% and 60.0%, respectively. The ELISA gave inconsistent results, and the genus-level LAMP agreed poorly with the other tests. Conclusions The choice of reference standard strongly influenced both accuracy and prevalence estimates, which could lead to divergent control decisions. Dra1 qPCR showed the strongest rule-out performance across reference frameworks, while the consistent sensitivity and modest infrastructure requirements of Sh -LAMP support its further evaluation for point-of-care testing in resource-limited settings.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-23
DOI
https://doi.org/10.21203/rs.3.rs-11691498/v1
Primary Topic
Parasites and Host Interactions
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Diagnostic accuracy of molecular and non-molecular assays for urogenital schistosomiasis in Zambian schoolchildren: a latent class and composite reference standard analysis

Antonio Muro, David Carmena, James C. L. Mwansa, Nilanjan Lodh et al.
Research Square
Parasites and Host Interactions
preprint

Diagnostic accuracy of molecular and non-molecular assays for urogenital schistosomiasis in Zambian schoolchildren: a latent class and composite reference standard analysis

Antonio Muro, David Carmena, James C. L. Mwansa, Nilanjan Lodh, Pedro Fernández‐Soto, Javier Sotillo, Mable Mwale Mutengo, María Jesús Perteguer, Begoña Crego-Vicente
preprint en

Abstract

Background Diagnosis of urogenital schistosomiasis is hampered by the lack of a true gold standard, as urine microscopy misses light and early infections. This study aimed to compare the diagnostic performance of molecular and non-molecular assays for urogenital schistosomiasis using different reference standards. Methods We evaluated three molecular assays (Dra1 qPCR, a species-specific LAMP for Schistosoma haematobium [Sh-LAMP] and a genus-specific Schistosoma LAMP) alongside urine microscopy, dipstick microhaematuria and a Sh -TSP-2 ELISA in 89 urine samples from schoolchildren in Lusaka Province, Zambia. Performance was assessed against microscopy, latent class analysis (LCA) and a composite reference standard (CRS). Sensitivity, specificity, likelihood ratios, predictive values and overall accuracy were calculated, and pairwise agreement between tests was assessed by correlation analysis. Results Microscopy identified 31 infected children (34.8%; 95% CI 25.0–45.7), compared with 35 (39.3%; 95% CI 29.1–50.3) by LCA and 55 (61.8%; 95% CI 50.9–71.9) by CRS. qPCR had the highest sensitivity in all three analyses (96.4–100%). Sh-LAMP was less sensitive than qPCR, with sensitivities of 87.1%, 85.7%, and 87.3% against microscopy, LCA, and the CRS, respectively. However, it achieved the highest overall accuracy of the molecular assays against microscopy and the CRS (58.4% and 78.7%, respectively). Microscopy and microhaematuria were fully specific under LCA and CRS, although their sensitivity against the CRS was only 56.4% and 60.0%, respectively. The ELISA gave inconsistent results, and the genus-level LAMP agreed poorly with the other tests. Conclusions The choice of reference standard strongly influenced both accuracy and prevalence estimates, which could lead to divergent control decisions. Dra1 qPCR showed the strongest rule-out performance across reference frameworks, while the consistent sensitivity and modest infrastructure requirements of Sh -LAMP support its further evaluation for point-of-care testing in resource-limited settings.

Research Square
Marquette University (US), Universidad de Salamanca (ES), Instituto de Salud Carlos III (ES), Lusaka Apex Medical University (ZM), Levy Mwanawasa Medical University (ZM)
Parasites and Host Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon