Design and Nonlinear Force Compensation of an Integrated Knee Distractor for Soft Tissue Balancing in TKA

In total knee arthroplasty (TKA), reliable distractor force measurement is required for quantitative soft-tissue balance assessment. Existing mechanical tensors, passive pressure-sensing trials, and force-controlled systems have improved measurement objectivity, but device deformation, assembly effects, and changing contact conditions can still introduce system-specific error. This study developed an integrated knee distractor with dual-channel independent actuation, force feedback, and distraction-gap detection. Rather than treating the BP neural network as an algorithmic innovation, the study focuses on a device-specific integration of structural design, mechanism-based error characterization, and calibrated nonlinear correction. The load-bearing path was represented by a Γ-shaped cantilever beam model. At a 10 mm distraction gap, the estimated structural-deformation component accounted for an average of 44.20% of the total force discrepancy across the tested loads (range, 32.47%-71.37%), indicating that both structural and non-structural error sources required consideration. A lightweight BP implementation with cubic-spline resampling was then used to model the remaining nonlinear relationship between distraction gap, measured force, and reference load. Under bench-top vertical spacer loading at simulated 0° knee extension, the within-grid assessment yielded a mean absolute error of 0.1671 N, a root mean square error of 0.2020 N, and a maximum error of 0.5074 N; five separately acquired validation conditions produced errors from − 0.20 to + 0.33 N. These results support the feasibility of the integrated structure-and-calibration workflow within the tested bench conditions, while multi-angle and clinically representative validation remains necessary.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-23
DOI
https://doi.org/10.21203/rs.3.rs-10835825/v1
Primary Topic
Total Knee Arthroplasty Outcomes
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Design and Nonlinear Force Compensation of an Integrated Knee Distractor for Soft Tissue Balancing in TKA

Enkui Zhang, He Xu, Tailin Han, Mingchi Ju et al.
Research Square
Total Knee Arthroplasty Outcomes
preprint

Design and Nonlinear Force Compensation of an Integrated Knee Distractor for Soft Tissue Balancing in TKA

Enkui Zhang, He Xu, Tailin Han, Mingchi Ju, Xuan Liu, Jun Hu, Ke Xu
preprint en

Abstract

In total knee arthroplasty (TKA), reliable distractor force measurement is required for quantitative soft-tissue balance assessment. Existing mechanical tensors, passive pressure-sensing trials, and force-controlled systems have improved measurement objectivity, but device deformation, assembly effects, and changing contact conditions can still introduce system-specific error. This study developed an integrated knee distractor with dual-channel independent actuation, force feedback, and distraction-gap detection. Rather than treating the BP neural network as an algorithmic innovation, the study focuses on a device-specific integration of structural design, mechanism-based error characterization, and calibrated nonlinear correction. The load-bearing path was represented by a Γ-shaped cantilever beam model. At a 10 mm distraction gap, the estimated structural-deformation component accounted for an average of 44.20% of the total force discrepancy across the tested loads (range, 32.47%-71.37%), indicating that both structural and non-structural error sources required consideration. A lightweight BP implementation with cubic-spline resampling was then used to model the remaining nonlinear relationship between distraction gap, measured force, and reference load. Under bench-top vertical spacer loading at simulated 0° knee extension, the within-grid assessment yielded a mean absolute error of 0.1671 N, a root mean square error of 0.2020 N, and a maximum error of 0.5074 N; five separately acquired validation conditions produced errors from − 0.20 to + 0.33 N. These results support the feasibility of the integrated structure-and-calibration workflow within the tested bench conditions, while multi-angle and clinically representative validation remains necessary.

Research Square
Changchun University of Science and Technology (CN)
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon