Occupant-Centric IEQ Performance Metrics for Green-Certified Higher Educational Buildings in Warm-Humid Climate: A Regression and IPA-Based Framework

India’s Green Building Rating System (GRIHA) has progressively expanded its Indoor Environmental Quality (IEQ) provisions, yet these remain based on design-stage documentation rather than empirically measured occupant priorities, particularly for warm-humid higher educational buildings. This study addresses that gap by combining regression-based importance weighting with framework-level and occupant-level Importance-Performance Analysis (IPA), drawing on post-occupancy surveys of 981 occupants across two GRIHA-certified higher educational buildings in South India (3-Star, n = 208; 4-Star, n = 773). Multiple regression identified Acoustic Comfort as the strongest predictor of perceived productivity (beta = 0.514, p < 0.001), followed by Spatial Comfort (beta = 0.198, p < 0.001); Indoor Air Quality was not a significant predictor (beta = 0.024, p = 0.298), with the model explaining 76.3% of variance (R2 = 0.763). Framework-level IPA placed Acoustic and Spatial Comfort in the under-invested quadrant (high regression beta, low GRIHA allocation), while Indoor Air Quality, which receives 54% of GRIHA’s IEQ points, fell in the over-invested quadrant (low beta, high allocation). Occupant-level IPA rated Acoustic Comfort as the most important domain and identified Spatial Comfort as the only domain in the Concentrate Here quadrant, and an independently derived Bayesian estimate of domain weights ranked Acoustic Comfort highest and Indoor Air Quality lowest, in agreement with the regression. Based on these findings, a recalibration is proposed: acoustic weighting increased from 2 to 5 points (partly mandatory), a new 3-point Spatial Comfort criterion introduced, IAQ allocation reduced from 7 to 4 points, with credit routes adapted to ventilation mode, and a voluntary 2-point post-occupancy evaluation bonus added, broadly consistent with LEED v5’s parallel shift toward occupant-experience criteria.

Authors

Institutions

Publication Details

Journal
Architecture
Published
2026-11-23
DOI
https://doi.org/10.3390/architecture6040223
Primary Topic
Sustainable Building Design and Assessment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Occupant-Centric IEQ Performance Metrics for Green-Certified Higher Educational Buildings in Warm-Humid Climate: A Regression and IPA-Based Framework

Anitha Suseelan, Abinaya J
Architecture
Sustainable Building Design and Assessment
article

Occupant-Centric IEQ Performance Metrics for Green-Certified Higher Educational Buildings in Warm-Humid Climate: A Regression and IPA-Based Framework

Anitha Suseelan, Abinaya J
article en

Abstract

India’s Green Building Rating System (GRIHA) has progressively expanded its Indoor Environmental Quality (IEQ) provisions, yet these remain based on design-stage documentation rather than empirically measured occupant priorities, particularly for warm-humid higher educational buildings. This study addresses that gap by combining regression-based importance weighting with framework-level and occupant-level Importance-Performance Analysis (IPA), drawing on post-occupancy surveys of 981 occupants across two GRIHA-certified higher educational buildings in South India (3-Star, n = 208; 4-Star, n = 773). Multiple regression identified Acoustic Comfort as the strongest predictor of perceived productivity (beta = 0.514, p < 0.001), followed by Spatial Comfort (beta = 0.198, p < 0.001); Indoor Air Quality was not a significant predictor (beta = 0.024, p = 0.298), with the model explaining 76.3% of variance (R2 = 0.763). Framework-level IPA placed Acoustic and Spatial Comfort in the under-invested quadrant (high regression beta, low GRIHA allocation), while Indoor Air Quality, which receives 54% of GRIHA’s IEQ points, fell in the over-invested quadrant (low beta, high allocation). Occupant-level IPA rated Acoustic Comfort as the most important domain and identified Spatial Comfort as the only domain in the Concentrate Here quadrant, and an independently derived Bayesian estimate of domain weights ranked Acoustic Comfort highest and Indoor Air Quality lowest, in agreement with the regression. Based on these findings, a recalibration is proposed: acoustic weighting increased from 2 to 5 points (partly mandatory), a new 3-point Spatial Comfort criterion introduced, IAQ allocation reduced from 7 to 4 points, with credit routes adapted to ventilation mode, and a voluntary 2-point post-occupancy evaluation bonus added, broadly consistent with LEED v5’s parallel shift toward occupant-experience criteria.

ArchitectureVol. 6(4)
Christ University (IN)
Sustainable Building Design and Assessment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Occupant-Centric IEQ Performance Metrics for Green-Certified Higher Educational Buildings in Warm-Humid Climate: A Regression and IPA-Based Framework — Anitha Suseelan, Abinaya J · Architecture (2026) | TGRS Research Map | TGRS