MAUDE-Atlas: a deduplicated, leakage-controlled and terminology-coded derivative of the FDA MAUDE medical device adverse event reports

MAUDE-Atlas v1.0.0 is a derivative of the public FDA Manufacturer and User Facility Device Experience (MAUDE) database, built from the openFDA device event endpoint on 30 August 2026. It contains 25,711,469 medical device adverse event reports, joined to patient records, report narratives, device identifiers and enforcement recall data, and coded against the official FDA MDR adverse-event terminology, which embeds the IMDRF annex A-G terms. Near-duplicate reports (MinHash/LSH, Jaccard >= 0.85) are grouped into 1,186,060 multi-report clusters and flagged, not removed. Reports are assigned to temporal training, validation and test partitions and to an out-of-distribution test set built from a 20% product-code holdout, with cluster-level leakage control. We report quality-control gates, a precision check on 200 sampled duplicate clusters, and three baseline results: severity classification (macro-F1 0.636 on the temporal test split), disproportionality signal detection (ROR AUC 0.561, PRR AUC 0.552) and link prediction (Hits@10 0.123). A free stratified sample of 100,003 reports is deposited on Zenodo under CC BY 4.0. The data support work on post-market surveillance, signal detection, text-based severity modelling and graph benchmarks. They are not validated for clinical decisions.

Authors

Publication Details

Journal
Research Square
Published
2026-11-23
DOI
https://doi.org/10.21203/rs.3.rs-11789568/v1
Primary Topic
Pharmacovigilance and Adverse Drug Reactions
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

MAUDE-Atlas: a deduplicated, leakage-controlled and terminology-coded derivative of the FDA MAUDE medical device adverse event reports

Chekerskyi Maksym
Research Square
Pharmacovigilance and Adverse Drug Reactions
preprint

MAUDE-Atlas: a deduplicated, leakage-controlled and terminology-coded derivative of the FDA MAUDE medical device adverse event reports

Chekerskyi Maksym
preprint en

Abstract

MAUDE-Atlas v1.0.0 is a derivative of the public FDA Manufacturer and User Facility Device Experience (MAUDE) database, built from the openFDA device event endpoint on 30 August 2026. It contains 25,711,469 medical device adverse event reports, joined to patient records, report narratives, device identifiers and enforcement recall data, and coded against the official FDA MDR adverse-event terminology, which embeds the IMDRF annex A-G terms. Near-duplicate reports (MinHash/LSH, Jaccard >= 0.85) are grouped into 1,186,060 multi-report clusters and flagged, not removed. Reports are assigned to temporal training, validation and test partitions and to an out-of-distribution test set built from a 20% product-code holdout, with cluster-level leakage control. We report quality-control gates, a precision check on 200 sampled duplicate clusters, and three baseline results: severity classification (macro-F1 0.636 on the temporal test split), disproportionality signal detection (ROR AUC 0.561, PRR AUC 0.552) and link prediction (Hits@10 0.123). A free stratified sample of 100,003 reports is deposited on Zenodo under CC BY 4.0. The data support work on post-market surveillance, signal detection, text-based severity modelling and graph benchmarks. They are not validated for clinical decisions.

Research Square
Pharmacovigilance and Adverse Drug Reactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.