Effectiveness and safety of a double-channel laryngeal mask airway during percutaneous endoscopic transgastric jejunostomy in patients with advanced Parkinson’s disease: a retrospective two-arm study

Patients with advanced Parkinson’s disease (PD), who are generally elderly and have comorbidities, often require the placement of a PEG-J, an advanced endoscopic procedure performed under sedation. Limited data are available, in this setting, on the double-channel Gastro-laryngeal mask airway (LMA). The study therefore aimed to investigate whether the use of the Gastro LMA, compared with a standard mouthpiece, could facilitate PEG-J procedures under moderate sedation in patients with advanced PD, while providing effective airway management and an acceptable safety profile. A retrospective two-arm analysis was conducted on PEG-J procedures performed under moderate sedation, comparing patients managed with the Gastro LMA and those with a Medtronic Microstream™ Advance Bite Block CO 2 filter line with O 2 tubing. The co-primary outcomes were gastric intubation time and overall procedure time. Secondary outcomes included procedural effectiveness, safety, sedative drug requirements, and anaesthesia monitoring parameters (EtCO₂ and SpO₂). Ninety-three PEG-J procedures were included in the analysis (72% were replacements), with 73.1% performed using the Gastro LMA in patients 63.4% with an ASA score > 2. With comparable procedural durations (Holm-adjusted P = 0.063), the success rate was 100% in the LMA group and 92% in the Microstream™ Advance Bite Block. Gastric intubation time was shorter in the Gastro LMA group (Hodges–Lehmann difference: −34.0 s; 95% CI: −50.0 to − 23.0; Holm-adjusted P < 0.0001). The adverse event rate was lower in the LMA group compared to the control group (1.5% vs. 16%, P = 0.018). This series suggests that the Gastro LMA may offer advantages over the standard mouthpiece in PEG-J procedures. Further prospective evidence is needed.

Authors

Institutions

Publication Details

Journal
BMC Gastroenterology
Published
2026-11-23
DOI
https://doi.org/10.1186/s12876-026-05571-1
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Effectiveness and safety of a double-channel laryngeal mask airway during percutaneous endoscopic transgastric jejunostomy in patients with advanced Parkinson’s disease: a retrospective two-arm study

Raffaele Pellegrino, Antonietta Gerarda Gravina, Sara Manzoni, Fausto Ferraro et al.
BMC Gastroenterology
Airway Management and Intubation Techniques
article

Effectiveness and safety of a double-channel laryngeal mask airway during percutaneous endoscopic transgastric jejunostomy in patients with advanced Parkinson’s disease: a retrospective two-arm study

Raffaele Pellegrino, Antonietta Gerarda Gravina, Sara Manzoni, Fausto Ferraro, Massimo Ciaravola, Alessandro Federico, Francesca Maria Pagnozzi, Anna Piedepalumbo
article en

Abstract

Patients with advanced Parkinson’s disease (PD), who are generally elderly and have comorbidities, often require the placement of a PEG-J, an advanced endoscopic procedure performed under sedation. Limited data are available, in this setting, on the double-channel Gastro-laryngeal mask airway (LMA). The study therefore aimed to investigate whether the use of the Gastro LMA, compared with a standard mouthpiece, could facilitate PEG-J procedures under moderate sedation in patients with advanced PD, while providing effective airway management and an acceptable safety profile. A retrospective two-arm analysis was conducted on PEG-J procedures performed under moderate sedation, comparing patients managed with the Gastro LMA and those with a Medtronic Microstream™ Advance Bite Block CO 2 filter line with O 2 tubing. The co-primary outcomes were gastric intubation time and overall procedure time. Secondary outcomes included procedural effectiveness, safety, sedative drug requirements, and anaesthesia monitoring parameters (EtCO₂ and SpO₂). Ninety-three PEG-J procedures were included in the analysis (72% were replacements), with 73.1% performed using the Gastro LMA in patients 63.4% with an ASA score > 2. With comparable procedural durations (Holm-adjusted P = 0.063), the success rate was 100% in the LMA group and 92% in the Microstream™ Advance Bite Block. Gastric intubation time was shorter in the Gastro LMA group (Hodges–Lehmann difference: −34.0 s; 95% CI: −50.0 to − 23.0; Holm-adjusted P < 0.0001). The adverse event rate was lower in the LMA group compared to the control group (1.5% vs. 16%, P = 0.018). This series suggests that the Gastro LMA may offer advantages over the standard mouthpiece in PEG-J procedures. Further prospective evidence is needed.

BMC Gastroenterology
University of Campania "Luigi Vanvitelli" (IT)
Airway Management and Intubation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon