Development and validation of Oncalyx, a digital tool for chemotherapy dose calculation: Content validity, computational accuracy and usability

BackgroundChemotherapy dosing integrates body size, organ function, regimen rules, dose banding and cumulative limits. Manual calculations and unvalidated calculators may introduce errors, while few tools provide transparent calculations tailored to local clinical practice.ObjectiveTo develop Oncalyx and evaluate its content validity, computational accuracy and usability.MethodsA web-based, server-side engine incorporated 156 version-controlled rules covering 26 regimens and organ-function adjustments for 25 drugs, derived from guidelines and pivotal trials. Ten oncology professionals (four oncologists, three pharmacists, three nurses) evaluated 21 content-validity items. Independently calculated reference doses for 30 synthetic cases spanning nine clinical profiles (65 drug lines) were compared with Oncalyx outputs at ±1% and ±5% tolerances, using Bland-Altman analysis and Lin's concordance correlation coefficient (CCC). Ninety-two automated test vectors were executed. Usability was evaluated through six observed tasks, the Single Ease Question (SEQ) and System Usability Scale (SUS).ResultsAll items achieved item-level content validity indices ≥0.90 (S-CVI/Ave 0.98; S-CVI/UA 0.81); 99.0% of correctness ratings were positive. Body surface area and creatinine clearance agreed within ±1% across all cases. Among 64 evaluable drug lines, 62 (96.9%) agreed within ±1% and 63 (98.4%) within ±5% (bias -0.02%; CCC 0.999). The largest discrepancy (-19.9%) reflected a reference error, not an Oncalyx error. All automated tests passed. Unaided task completion was 98.3%, without critical errors (mean SEQ 6.62/7; SUS 89.0, 95% CI 84.4-93.6).ConclusionsIn this preliminary evaluation, Oncalyx showed excellent content validity, computational agreement and usability. Transparent calculations, unit checks and version-stamped dose sheets facilitate independent verification; larger, multicentre, real-world evaluation is needed before wider use.

Authors

Institutions

Publication Details

Journal
Journal of Oncology Pharmacy Practice
Published
2026-11-23
DOI
https://doi.org/10.1177/10781552261509984
Primary Topic
Electronic Health Records Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Development and validation of Oncalyx, a digital tool for chemotherapy dose calculation: Content validity, computational accuracy and usability

Praneet Bedi, Naureen Imran, Ganesh BH, Alim Shaikh
Journal of Oncology Pharmacy Practice
Electronic Health Records Systems
article

Development and validation of Oncalyx, a digital tool for chemotherapy dose calculation: Content validity, computational accuracy and usability

Praneet Bedi, Naureen Imran, Ganesh BH, Alim Shaikh
article en

Abstract

BackgroundChemotherapy dosing integrates body size, organ function, regimen rules, dose banding and cumulative limits. Manual calculations and unvalidated calculators may introduce errors, while few tools provide transparent calculations tailored to local clinical practice.ObjectiveTo develop Oncalyx and evaluate its content validity, computational accuracy and usability.MethodsA web-based, server-side engine incorporated 156 version-controlled rules covering 26 regimens and organ-function adjustments for 25 drugs, derived from guidelines and pivotal trials. Ten oncology professionals (four oncologists, three pharmacists, three nurses) evaluated 21 content-validity items. Independently calculated reference doses for 30 synthetic cases spanning nine clinical profiles (65 drug lines) were compared with Oncalyx outputs at ±1% and ±5% tolerances, using Bland-Altman analysis and Lin's concordance correlation coefficient (CCC). Ninety-two automated test vectors were executed. Usability was evaluated through six observed tasks, the Single Ease Question (SEQ) and System Usability Scale (SUS).ResultsAll items achieved item-level content validity indices ≥0.90 (S-CVI/Ave 0.98; S-CVI/UA 0.81); 99.0% of correctness ratings were positive. Body surface area and creatinine clearance agreed within ±1% across all cases. Among 64 evaluable drug lines, 62 (96.9%) agreed within ±1% and 63 (98.4%) within ±5% (bias -0.02%; CCC 0.999). The largest discrepancy (-19.9%) reflected a reference error, not an Oncalyx error. All automated tests passed. Unaided task completion was 98.3%, without critical errors (mean SEQ 6.62/7; SUS 89.0, 95% CI 84.4-93.6).ConclusionsIn this preliminary evaluation, Oncalyx showed excellent content validity, computational agreement and usability. Transparent calculations, unit checks and version-stamped dose sheets facilitate independent verification; larger, multicentre, real-world evaluation is needed before wider use.

Journal of Oncology Pharmacy Practice
DY Patil Deemed to be University (IN)
Electronic Health Records Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon