Effect of High‐Speed Railway Operational Conditions on the Dynamic AC Corrosion Behavior and Mechanisms of Pipeline Steel

High‐speed railway operation induces dynamic AC interference on nearby buried steel pipelines, with periodic operating and shutdown periods. A dynamic AC corrosion simulation system incorporating AC current density, cathodic protection level, and shutdown period is established to investigate corrosion behavior and mechanism. The corrosion rate increases with increasing dynamic AC current density and first decreases and then increases with a negative shift in cathodic protection potential. Increasing the shutdown period from 0 to 6 h reduces corrosion rates under different cathodic protection conditions. Under a 5 h shutdown period, 300 A/m 2 AC interference, and −1.15 V SCE cathodic protection, the corrosion rate decreases from 1.047 mm/y after 19 h operation to 0.932 mm/y after 5 h shutdown and further stabilizes at approximately 0.52 mm/y after multiple operating–shutdown cycles. Shutdown‐period cathodic protection promotes corrosion product film stabilization and enhances corrosion resistance, revealing the mitigation mechanism of dynamic AC corrosion during high‐speed railway operational cycles.

Authors

Institutions

Publication Details

Journal
Materials and Corrosion
Published
2026-11-23
DOI
https://doi.org/10.1002/maco.70320
Primary Topic
Corrosion Behavior and Inhibition
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Effect of High‐Speed Railway Operational Conditions on the Dynamic AC Corrosion Behavior and Mechanisms of Pipeline Steel

Yanxia Du, Shanshan Dong, Jiaze Sun, Le Chen
Materials and Corrosion
Corrosion Behavior and Inhibition
article

Effect of High‐Speed Railway Operational Conditions on the Dynamic AC Corrosion Behavior and Mechanisms of Pipeline Steel

Yanxia Du, Shanshan Dong, Jiaze Sun, Le Chen
article en

Abstract

High‐speed railway operation induces dynamic AC interference on nearby buried steel pipelines, with periodic operating and shutdown periods. A dynamic AC corrosion simulation system incorporating AC current density, cathodic protection level, and shutdown period is established to investigate corrosion behavior and mechanism. The corrosion rate increases with increasing dynamic AC current density and first decreases and then increases with a negative shift in cathodic protection potential. Increasing the shutdown period from 0 to 6 h reduces corrosion rates under different cathodic protection conditions. Under a 5 h shutdown period, 300 A/m 2 AC interference, and −1.15 V SCE cathodic protection, the corrosion rate decreases from 1.047 mm/y after 19 h operation to 0.932 mm/y after 5 h shutdown and further stabilizes at approximately 0.52 mm/y after multiple operating–shutdown cycles. Shutdown‐period cathodic protection promotes corrosion product film stabilization and enhances corrosion resistance, revealing the mitigation mechanism of dynamic AC corrosion during high‐speed railway operational cycles.

Materials and Corrosion
University of Science and Technology Beijing (CN)
Corrosion Behavior and Inhibition
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon