Detection of synthetically generated heat pump COP degradation under varying operating conditions: a comparison of a COP threshold and a Hist Gradient Boosting model

Heat pump Coefficient of Performance (COP) changes naturally with operating conditions, so a single fixed COP threshold may cause an incorrect interpretation of a normal change in operating point as performance degradation. This study examines whether supervised machine learning can distinguish synthetically generated COP degradation from such normal operating changes more reliably than a fixed threshold. We used the public AI-DHC synthetic benchmark, with 100 simulations from boundary conditions bc01-bc04 for training (329,115 time-point observations) and 10 disjoint bc00 simulations for testing (40,032 observations). Ten predefined classifier configurations were compared. Hist Gradient Boosting (HGB) provided the best result among the tested configurations. Its F1 score, which balances precision and recall, was 0.895, compared with 0.601 for the training-derived COP≤1.83 threshold. Detection was easier for abrupt degradation than for progressive degradation, and the earliest stage of progressive degradation remained the most difficult to identify. Additional analyses showed that thermal and electrical power carried most of the diagnostic information, while the wider operating context improved performance further. The findings apply only to controlled synthetic data and do not demonstrate performance on real heat pump installations. They nevertheless show why a multivariable model that interprets efficiency in its operating context can be more robust than one global COP threshold when boundary conditions change.

Authors

Institutions

Publication Details

Journal
Journal of Sustainable Technologies
Published
2026-11-23
DOI
https://doi.org/10.5604/01.3001.0055.9841
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Detection of synthetically generated heat pump COP degradation under varying operating conditions: a comparison of a COP threshold and a Hist Gradient Boosting model

Kamil Łodygowski, Adam Ciesielski, Jan Sobczak Paweł
Journal of Sustainable Technologies
Fault Detection and Control Systems
article

Detection of synthetically generated heat pump COP degradation under varying operating conditions: a comparison of a COP threshold and a Hist Gradient Boosting model

Kamil Łodygowski, Adam Ciesielski, Jan Sobczak Paweł
article en

Abstract

Heat pump Coefficient of Performance (COP) changes naturally with operating conditions, so a single fixed COP threshold may cause an incorrect interpretation of a normal change in operating point as performance degradation. This study examines whether supervised machine learning can distinguish synthetically generated COP degradation from such normal operating changes more reliably than a fixed threshold. We used the public AI-DHC synthetic benchmark, with 100 simulations from boundary conditions bc01-bc04 for training (329,115 time-point observations) and 10 disjoint bc00 simulations for testing (40,032 observations). Ten predefined classifier configurations were compared. Hist Gradient Boosting (HGB) provided the best result among the tested configurations. Its F1 score, which balances precision and recall, was 0.895, compared with 0.601 for the training-derived COP≤1.83 threshold. Detection was easier for abrupt degradation than for progressive degradation, and the earliest stage of progressive degradation remained the most difficult to identify. Additional analyses showed that thermal and electrical power carried most of the diagnostic information, while the wider operating context improved performance further. The findings apply only to controlled synthetic data and do not demonstrate performance on real heat pump installations. They nevertheless show why a multivariable model that interprets efficiency in its operating context can be more robust than one global COP threshold when boundary conditions change.

Journal of Sustainable TechnologiesVol. 117(2)
State University of Applied Sciences in Konin (PL)
Fault Detection and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Detection of synthetically generated heat pump COP degradation under varying operating conditions: a comparison of a COP threshold and a Hist Gradient Boosting model — Kamil Łodygowski, Adam Ciesielski, et al. · Journal of Sustainable Technologies (2026) | TGRS Research Map | TGRS