Coordinated Fault Ride-Through Control for a Hierarchically Connected VSC-HVDC System

As voltage-source converter-based high-voltage direct-current (VSC-HVDC) transmission systems evolve toward higher power ratings and voltage levels, a hierarchical configuration in which series-connected receiving-end converter units are connected to AC grids at different voltage levels introduces additional challenges in interlayer power coordination and fault ride-through (FRT). During a severe receiving-end AC voltage sag, the active power transfer capability of the faulted converter decreases markedly, whereas the sending-end input power cannot be reduced instantaneously. The resulting surplus power is absorbed by the submodule capacitors of the modular multilevel converter (MMC), leading to capacitor overvoltage. Under asymmetrical faults, pronounced second-harmonic active power oscillations also arise. To address these issues, control-oriented decoupling between the submodule capacitor voltage and the DC terminal voltage is first established, and a supplementary voltage reference is generated according to the average submodule capacitor voltage. The DC voltage references of the faulted and healthy converters are then coordinately adjusted to redistribute the DC voltage and active power between the receiving-end layers. When the healthy converter reaches its operating limit, an auxiliary DC current control is activated to achieve automatic sending-end power reduction. For asymmetrical faults, the second-harmonic active power component is further extracted from the AC- and DC-side active powers of the faulted MMC, and the resulting compensation term is superimposed on the capacitor overvoltage regulation term to form a composite supplementary voltage reference. CloudPSS simulation results demonstrate that the proposed control effectively utilizes the available transmission capability of the healthy converter, limits submodule capacitor overvoltage and excessive DC current rise, and mitigates second-harmonic active power oscillations under asymmetrical faults, thereby enhancing the FRT performance of the hierarchically connected VSC-HVDC system.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-11-23
DOI
https://doi.org/10.3390/en19235668
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Coordinated Fault Ride-Through Control for a Hierarchically Connected VSC-HVDC System

Jianyu Zhou, Zhiyong Zhang, Pen Gu, Lilong Zhou et al.
Energies
HVDC Systems and Fault Protection
article

Coordinated Fault Ride-Through Control for a Hierarchically Connected VSC-HVDC System

Jianyu Zhou, Zhiyong Zhang, Pen Gu, Lilong Zhou, Wei Wei, Peng Zhang
article en

Abstract

As voltage-source converter-based high-voltage direct-current (VSC-HVDC) transmission systems evolve toward higher power ratings and voltage levels, a hierarchical configuration in which series-connected receiving-end converter units are connected to AC grids at different voltage levels introduces additional challenges in interlayer power coordination and fault ride-through (FRT). During a severe receiving-end AC voltage sag, the active power transfer capability of the faulted converter decreases markedly, whereas the sending-end input power cannot be reduced instantaneously. The resulting surplus power is absorbed by the submodule capacitors of the modular multilevel converter (MMC), leading to capacitor overvoltage. Under asymmetrical faults, pronounced second-harmonic active power oscillations also arise. To address these issues, control-oriented decoupling between the submodule capacitor voltage and the DC terminal voltage is first established, and a supplementary voltage reference is generated according to the average submodule capacitor voltage. The DC voltage references of the faulted and healthy converters are then coordinately adjusted to redistribute the DC voltage and active power between the receiving-end layers. When the healthy converter reaches its operating limit, an auxiliary DC current control is activated to achieve automatic sending-end power reduction. For asymmetrical faults, the second-harmonic active power component is further extracted from the AC- and DC-side active powers of the faulted MMC, and the resulting compensation term is superimposed on the capacitor overvoltage regulation term to form a composite supplementary voltage reference. CloudPSS simulation results demonstrate that the proposed control effectively utilizes the available transmission capability of the healthy converter, limits submodule capacitor overvoltage and excessive DC current rise, and mitigates second-harmonic active power oscillations under asymmetrical faults, thereby enhancing the FRT performance of the hierarchically connected VSC-HVDC system.

EnergiesVol. 19(23)
State Grid Corporation of China (China) (CN), Sichuan University (CN), Shanghai Electric (China) (CN)
State Grid Corporation of China, Science and Technology Project of State Grid
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon