Cloud-Aware Thermal Anomaly Detection in Tropical Peatlands Using First-Order Neighborhood Mean-Shift and MODIS Multispectral Imagery

Underground peat fires are difficult to detect using satellite observations because their thermal signatures can be weak and spatially mixed with vegetation, water, and cloud contamination, particularly in tropical peatland environments. This study proposes a cloud-aware multispectral framework for detecting potential underground peat-fire thermal anomalies from Moderate-Resolution Imaging Spectroradiometer (MODIS) observations over the Khuan Khreng Peat Swamp Forest, Thailand. The framework integrates a proposed First-Order Neighborhood Mean-Shift (FNM) segmentation algorithm, valid-land masking, multispectral feature representation, and Support Vector Machine (SVM) classification. FNM constrains feature updates within a bounded first-order neighborhood to preserve local spatial continuity while reducing computational complexity. On an annotated Landsat 8 segmentation benchmark, FNM achieved 92.00% accuracy, a 91.24% F1-score, and an 83.91% intersection over union (IoU), with an average runtime of 0.96 s per image. A masking-ablation experiment further demonstrated the contribution of FNM to downstream classification: FNM + SVM increased the F1-score from 57.75% without masking to 65.06% and reduced the false alarm rate from 7.82% to 5.88%. For the 2012–2015 Khuan Khreng evaluation dataset, the complete framework detected 95 of 118 reference fire observations and achieved an overall accuracy of 93.02%, recall of 80.51%, specificity of 94.12%, and F1-score of 65.07%. Feature-ablation experiments showed that thermal brightness-temperature variables provided the primary discriminatory information, while reflectance variables contributed complementary information, with the complete five-variable configuration achieving the highest classification performance. These findings demonstrate that the proposed FNM–SVM framework provides an effective integration of spatial segmentation, cloud-aware valid-land masking, and multispectral classification for mapping potential underground peat-fire thermal anomalies in cloud-prone tropical peatland environments.

Authors

Institutions

Publication Details

Journal
Remote Sensing
Published
2026-11-23
DOI
https://doi.org/10.3390/rs18234023
Primary Topic
Fire Detection and Safety Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Cloud-Aware Thermal Anomaly Detection in Tropical Peatlands Using First-Order Neighborhood Mean-Shift and MODIS Multispectral Imagery

Mahasak Ketcham, Thittaporn Ganokratanaa
Remote Sensing
Fire Detection and Safety Systems
article

Cloud-Aware Thermal Anomaly Detection in Tropical Peatlands Using First-Order Neighborhood Mean-Shift and MODIS Multispectral Imagery

Mahasak Ketcham, Thittaporn Ganokratanaa
article en

Abstract

Underground peat fires are difficult to detect using satellite observations because their thermal signatures can be weak and spatially mixed with vegetation, water, and cloud contamination, particularly in tropical peatland environments. This study proposes a cloud-aware multispectral framework for detecting potential underground peat-fire thermal anomalies from Moderate-Resolution Imaging Spectroradiometer (MODIS) observations over the Khuan Khreng Peat Swamp Forest, Thailand. The framework integrates a proposed First-Order Neighborhood Mean-Shift (FNM) segmentation algorithm, valid-land masking, multispectral feature representation, and Support Vector Machine (SVM) classification. FNM constrains feature updates within a bounded first-order neighborhood to preserve local spatial continuity while reducing computational complexity. On an annotated Landsat 8 segmentation benchmark, FNM achieved 92.00% accuracy, a 91.24% F1-score, and an 83.91% intersection over union (IoU), with an average runtime of 0.96 s per image. A masking-ablation experiment further demonstrated the contribution of FNM to downstream classification: FNM + SVM increased the F1-score from 57.75% without masking to 65.06% and reduced the false alarm rate from 7.82% to 5.88%. For the 2012–2015 Khuan Khreng evaluation dataset, the complete framework detected 95 of 118 reference fire observations and achieved an overall accuracy of 93.02%, recall of 80.51%, specificity of 94.12%, and F1-score of 65.07%. Feature-ablation experiments showed that thermal brightness-temperature variables provided the primary discriminatory information, while reflectance variables contributed complementary information, with the complete five-variable configuration achieving the highest classification performance. These findings demonstrate that the proposed FNM–SVM framework provides an effective integration of spatial segmentation, cloud-aware valid-land masking, and multispectral classification for mapping potential underground peat-fire thermal anomalies in cloud-prone tropical peatland environments.

Remote SensingVol. 18(23)
King Mongkut's University of Technology Thonburi (TH), King Mongkut's University of Technology North Bangkok (TH)
Fire Detection and Safety Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon