CdSe quantum dot-based photoelectrochemical and electrochemiluminescent biosensors: Structure–property relationships, signal mechanisms and analytical applications

Cadmium selenide (CdSe) quantum dots have attracted considerable interest in photoelectrochemical (PEC) and electrochemiluminescent (ECL) biosensing because of their tunable electronic structure, broad optical absorption, efficient charge transport, and favorable luminescence. This review examines the structure–property relationships governing CdSe performance in PEC and ECL platforms, emphasizing the roles of charge transfer, exciton dynamics, surface chemistry, and interfacial engineering in signal generation and amplification. The effects of size, morphology, crystal structure, heterostructure design, defects, and surface functionalization on sensitivity, selectivity, reproducibility, and operational stability are critically evaluated. Recent advances demonstrate that rationally engineered CdSe architectures can improve analytical performance across diverse biosensing applications. However, toxicity, batch-to-batch variability, signal drift, insufficient long-term stability, and limited validation in complex samples continue to restrict practical translation. To address these barriers, future research should prioritize cadmium-leakage-resistant shells, stable and biocompatible ligands, standardized synthesis and calibration protocols, accelerated aging tests, and validation using clinically or environmentally relevant samples. Integrating reference channels, antifouling interfaces, portable instrumentation, and interpretable data-processing methods may further support reliable, decentralized, and application-ready CdSe biosensing systems for precision healthcare and environmental monitoring applications.

Authors

Institutions

Publication Details

Journal
Next Materials
Published
2026-11-23
DOI
https://doi.org/10.1016/j.nxmate.2026.104087
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

CdSe quantum dot-based photoelectrochemical and electrochemiluminescent biosensors: Structure–property relationships, signal mechanisms and analytical applications

Ruchi Bharti, Rahul Saxena, Soumya Vettiyatil Menon, Harish Chandra Joshi et al.
Next Materials
Advanced biosensing and bioanalysis techniques
article

CdSe quantum dot-based photoelectrochemical and electrochemiluminescent biosensors: Structure–property relationships, signal mechanisms and analytical applications

Ruchi Bharti, Rahul Saxena, Soumya Vettiyatil Menon, Harish Chandra Joshi, Ruziyeva Gulsara, Asokan Vasudevan, Suleiman Ibrahim Mohammad, Saeid Mohebi, Hamza Farhan Abu Owida, Shamuratova Gulnora Baxtiyorovna
article en

Abstract

Cadmium selenide (CdSe) quantum dots have attracted considerable interest in photoelectrochemical (PEC) and electrochemiluminescent (ECL) biosensing because of their tunable electronic structure, broad optical absorption, efficient charge transport, and favorable luminescence. This review examines the structure–property relationships governing CdSe performance in PEC and ECL platforms, emphasizing the roles of charge transfer, exciton dynamics, surface chemistry, and interfacial engineering in signal generation and amplification. The effects of size, morphology, crystal structure, heterostructure design, defects, and surface functionalization on sensitivity, selectivity, reproducibility, and operational stability are critically evaluated. Recent advances demonstrate that rationally engineered CdSe architectures can improve analytical performance across diverse biosensing applications. However, toxicity, batch-to-batch variability, signal drift, insufficient long-term stability, and limited validation in complex samples continue to restrict practical translation. To address these barriers, future research should prioritize cadmium-leakage-resistant shells, stable and biocompatible ligands, standardized synthesis and calibration protocols, accelerated aging tests, and validation using clinically or environmentally relevant samples. Integrating reference channels, antifouling interfaces, portable instrumentation, and interpretable data-processing methods may further support reliable, decentralized, and application-ready CdSe biosensing systems for precision healthcare and environmental monitoring applications.

Next MaterialsVol. 14
Chandigarh University (IN), Al-Ahliyya Amman University (JO), Jain University (IN), Islamic Azad University, Tehran (IR), INTI International University (MY), Graphic Era Hill University (IN), Al al-Bayt University (JO), Termez University of Economics and Service (UZ), Mamun University (UZ), Graphic Era University (IN), Sharda University (IN)
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon