Comparing Heat Extraction from PWR-SMR and HTGR Power Cycles for Hydrogen and Sustainable Aviation Fuel Production

The cogeneration of heat as well as electricity from nuclear power plants offers a unique potential for de-carbonising a great number of industries, including the production of hydrogen via high-temperature steam electrolysis as an energy carrier or precursor to the further production of ammonia or carbon-neutral synthetic hydrocarbons. However, the extraction of heat from the power cycle of a nuclear reactor requires close coupling and must be optimised to minimise the impact to the efficiency of electricity generation, and so thereby achieve a high overall system efficiency. The design of the coupling of the reactor is specific to the reactor technology and the system or industry utilising the co-generated heat. As a case study, detailed simulations were created using gPROMS process modelling software to design and optimise the coupling of PWR-SMR and both open- and closed-cycle HTGRs to HTSE for hydrogen production and synthetic hydrocarbon (SAF) production for the aviation industry. It was found that design and selection of the location of heat extraction had a moderate impact on system efficiency. Key reactor operating parameters that must be adjusted during load balancing were identified; the most important of these are cycle flowrates, the Brayton pressure ratio, the degree of Rankine reheat, and the fraction of steam bled from Rankine turbine stages. Modelling results show that HTGRs are more efficient; also, switching a PWR-SMR from electricity to hydrogen cogeneration would result in a greater loss in electrical energy generation capacity per unit of hydrogen produced (141.52 MJe[lost] kg−1 H2) than from equivalently sized HTGRs (as low as 138.04 MJe[lost] kg−1 H2 [O-HTGR], or 138.47 MJe[lost] kg−1 H2 [C-HTGR]). This indicates that the most efficient strategy, given a mix of HTGRs and SMR-PWRs, would be to prioritise HTGRs for cogeneration.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-11-23
DOI
https://doi.org/10.3390/en19235675
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Comparing Heat Extraction from PWR-SMR and HTGR Power Cycles for Hydrogen and Sustainable Aviation Fuel Production

Matthew Horton, Mark Bankhead, Christopher Connolly, Alex Raw et al.
Energies
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

Comparing Heat Extraction from PWR-SMR and HTGR Power Cycles for Hydrogen and Sustainable Aviation Fuel Production

Matthew Horton, Mark Bankhead, Christopher Connolly, Alex Raw, Kate Taylor
article en

Abstract

The cogeneration of heat as well as electricity from nuclear power plants offers a unique potential for de-carbonising a great number of industries, including the production of hydrogen via high-temperature steam electrolysis as an energy carrier or precursor to the further production of ammonia or carbon-neutral synthetic hydrocarbons. However, the extraction of heat from the power cycle of a nuclear reactor requires close coupling and must be optimised to minimise the impact to the efficiency of electricity generation, and so thereby achieve a high overall system efficiency. The design of the coupling of the reactor is specific to the reactor technology and the system or industry utilising the co-generated heat. As a case study, detailed simulations were created using gPROMS process modelling software to design and optimise the coupling of PWR-SMR and both open- and closed-cycle HTGRs to HTSE for hydrogen production and synthetic hydrocarbon (SAF) production for the aviation industry. It was found that design and selection of the location of heat extraction had a moderate impact on system efficiency. Key reactor operating parameters that must be adjusted during load balancing were identified; the most important of these are cycle flowrates, the Brayton pressure ratio, the degree of Rankine reheat, and the fraction of steam bled from Rankine turbine stages. Modelling results show that HTGRs are more efficient; also, switching a PWR-SMR from electricity to hydrogen cogeneration would result in a greater loss in electrical energy generation capacity per unit of hydrogen produced (141.52 MJe[lost] kg−1 H2) than from equivalently sized HTGRs (as low as 138.04 MJe[lost] kg−1 H2 [O-HTGR], or 138.47 MJe[lost] kg−1 H2 [C-HTGR]). This indicates that the most efficient strategy, given a mix of HTGRs and SMR-PWRs, would be to prioritise HTGRs for cogeneration.

EnergiesVol. 19(23)
National Nuclear Laboratory (GB)
Government of the United Kingdom
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Comparing Heat Extraction from PWR-SMR and HTGR Power Cycles for Hydrogen and Sustainable Aviation Fuel Production — Matthew Horton, Mark Bankhead, et al. · Energies (2026) | TGRS Research Map | TGRS