Eco-efficient AQbD-based stability-indicating UPLC method development and validation for simultaneous determination of Avibactam and Aztreonam with integrated green, red, blue and white analytical assessment
An eco-efficient, stability-indicating ultra-performance liquid chromatographic (UPLC) method was developed and validated for the simultaneous determination of Avibactam (AVI) and Aztreonam (AZT) in pharmaceutical formulations using an Analytical Quality by Design (AQbD) approach. To promote sustainable method development, solvent selection was guided by the Hansen Solubility Parameter (HSP) space-based solvent selection strategy, leading to the selection of ethanol as a green alternative to conventional hazardous organic solvents. To the best of our knowledge, this is the first reported AQbD-based stability-indicating UPLC method for the simultaneous determination of AVI and AZT that integrates HSP-guided solvent selection with comprehensive Green, Red, Blue, and White analytical chemistry assessment. Critical method parameters were systematically optimized to ensure robust chromatographic performance and method reliability. Chromatographic separation was achieved on a Waters BEH C18 column (2.1 × 50 mm, 3.0 µm) using phosphate buffer (pH 6.0) and ethanol (30:70, v/v) as the mobile phase at a flow rate of 0.4 mL/min. Detection was carried out at 225 nm using a PDA detector with a 4 µL injection volume and a total run time of 8 min. The method was validated according to ICH guidelines and demonstrated excellent specificity, linearity, accuracy, precision, robustness, and sensitivity, with %RSD values below 2%. Forced degradation studies under acidic, alkaline, oxidative, thermal, and photolytic stress conditions confirmed the stability-indicating capability of the method by effectively separating degradation products from the analyte peaks. Sustainability and overall analytical quality were evaluated using GAPI, AGREE, AMGS, Carbon Footprint Analysis, RAPI, BAGI, and White Analytical Chemistry principles. The favourable RGB assessment outcomes demonstrated an excellent balance between environmental sustainability, analytical performance, practicality, and method excellence, supporting its suitability for routine Analysis.
Authors
- Manikandan Krishnan (ORCID: https://orcid.org/0000-0001-7434-8067)
- Vineetha Rosireddy (ORCID: https://orcid.org/0000-0003-0227-0250)
- Reshma Siraj
- Y. Ismail
Institutions
- SRM Institute of Science and Technology (IN)
- B.S. Abdur Rahman Crescent Institute of Science & Technology (IN)
Publication Details
- Journal
- BMC Chemistry
- Published
- 2026-11-22
- DOI
- https://doi.org/10.1186/s13065-026-01931-w
- Primary Topic
- Analytical Methods in Pharmaceuticals
- Type
- article
- Field-Weighted Citation Impact