Numerical Investigation of the Thermal–Hydraulic Performance of a Double‐Pipe Heat Exchanger With Porous Inserts

Double‐pipe heat exchangers (DPHEs) are widely used because of their simple design, operational reliability, and effective heat‐transfer capability. This study presents a three‐dimensional computational fluid dynamics (CFD) analysis of a counterflow DPHE fitted with interrupted and staggered (St.) segmented copper‐foam inserts in the annular region. Numerical simulations were performed using ANSYS Fluent, employing the Darcy–Brinkman–Forchheimer porous media model coupled with the local thermal nonequilibrium energy model to accurately predict the fluid flow and heat transfer within the porous structure. Ten porous configurations, comprising interrupted and staggered arrangements with different segment arrangements and configurations, were evaluated over a Reynolds number range of 205–1435. The thermo‐hydraulic performance was assessed using the Nusselt number, friction factor, and thermal performance factor (TPF). Compared with the smooth annulus, the interrupted configurations increased the average Nusselt number by 269.3%–293.7%, whereas the staggered configurations increased it by 308.6%–389.1%. These improvements were accompanied by an increase in the friction factor of 196.1%–213.5% and 259.6%–372.9%, respectively. Despite the additional pressure loss, all configurations produced TPF values greater than unity, ranging from 2.58 to 2.71 for interrupted arrangements and 2.70 to 3.00 for staggered arrangements, confirming an overall improvement in the thermo‐hydraulic performance. Although the optimum configuration varied with Re , the St.‐3–11 arrangement delivered the best overall performance across the investigated range, whereas St.‐3–5 achieved the highest TPF at Re = 205. These results demonstrate that segmented, staggered copper‐foam inserts provide an effective passive enhancement technique for compact, energy‐efficient DPHEs used in thermal energy storage, waste heat recovery, heating, ventilation, and air conditioning (HVAC) systems, and the process industry.

Authors

Institutions

Publication Details

Journal
Heat Transfer
Published
2026-11-22
DOI
https://doi.org/10.1002/htj.70426
Primary Topic
Heat Transfer Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Numerical Investigation of the Thermal–Hydraulic Performance of a Double‐Pipe Heat Exchanger With Porous Inserts

Govindappa Krishnappa, Uttamasha Gupta, Prabhukumar Sellamuthu, Seetharamapura Balaji Anjappa et al.
Heat Transfer
Heat Transfer Mechanisms
article

Numerical Investigation of the Thermal–Hydraulic Performance of a Double‐Pipe Heat Exchanger With Porous Inserts

Govindappa Krishnappa, Uttamasha Gupta, Prabhukumar Sellamuthu, Seetharamapura Balaji Anjappa, Mohit Kumar Agrawal, Shivaranjini
article en

Abstract

Double‐pipe heat exchangers (DPHEs) are widely used because of their simple design, operational reliability, and effective heat‐transfer capability. This study presents a three‐dimensional computational fluid dynamics (CFD) analysis of a counterflow DPHE fitted with interrupted and staggered (St.) segmented copper‐foam inserts in the annular region. Numerical simulations were performed using ANSYS Fluent, employing the Darcy–Brinkman–Forchheimer porous media model coupled with the local thermal nonequilibrium energy model to accurately predict the fluid flow and heat transfer within the porous structure. Ten porous configurations, comprising interrupted and staggered arrangements with different segment arrangements and configurations, were evaluated over a Reynolds number range of 205–1435. The thermo‐hydraulic performance was assessed using the Nusselt number, friction factor, and thermal performance factor (TPF). Compared with the smooth annulus, the interrupted configurations increased the average Nusselt number by 269.3%–293.7%, whereas the staggered configurations increased it by 308.6%–389.1%. These improvements were accompanied by an increase in the friction factor of 196.1%–213.5% and 259.6%–372.9%, respectively. Despite the additional pressure loss, all configurations produced TPF values greater than unity, ranging from 2.58 to 2.71 for interrupted arrangements and 2.70 to 3.00 for staggered arrangements, confirming an overall improvement in the thermo‐hydraulic performance. Although the optimum configuration varied with Re , the St.‐3–11 arrangement delivered the best overall performance across the investigated range, whereas St.‐3–5 achieved the highest TPF at Re = 205. These results demonstrate that segmented, staggered copper‐foam inserts provide an effective passive enhancement technique for compact, energy‐efficient DPHEs used in thermal energy storage, waste heat recovery, heating, ventilation, and air conditioning (HVAC) systems, and the process industry.

Heat Transfer
Presidency University (IN), Nitte Meenakshi Institute of Technology (IN), Visvesvaraya Technological University (IN)
Heat Transfer Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon