Chloride ion-induced reinforcement corrosion is one of the main causes of deterioration in reinforced concrete structures located in coastal areas. This study analyzes the effectiveness of lean concrete blinding as a protective barrier for shallow foundations. Three configurations were evaluated: conventional lean concrete, concrete with a crystalline waterproofing admixture, and conventional concrete with asphalt coating at the interface. The tests used soil and seawater from the Santos region, São Paulo, Brazil, with qualitative chloride identification using silver nitrate (AgNO₃). The results indicated that conventional concrete and the crystalline admixture did not prevent salt penetration. In contrast, the asphalt coating blocked chloride migration into the footing, demonstrating greater effectiveness as a physical barrier.