Microstructural changes in radiochromic film and dosimetry in magnetic field

Radiochromic film (RCF) dosimetry in magnetic resonance-guided linear accelerator systems requires validation due to conflicting reports regarding dosimetric accuracy in magnetic fields (MF). This study quantitatively evaluated microstructural changes and dosimetric response of EBT-3 RCFs exposed to ionizing radiation in a 0.35 T magnetic field. Films from a single batch were irradiated with 2, 5, 8, 10, and 16 Gy using a 6 MV flattening filter-free photon beam from a ViewRay magnetic resonance-linear accelerator unit, with and without magnetic field activation. Scanning electron microscopy (SEM) at 2500× magnification analyzed microstructural features, while quantitative measurements of needle-like crystal structures assessed length and angular orientation using ImageJ software. Optical density measurements employed standard RCF protocols with red-green-blue to grayscale conversion. Results demonstrated that crystal lengths remained consistent across all radiation doses regardless of magnetic field presence, with no statistically significant variations observed. However, magnetic field exposure produced dramatic angular alignment effects, with crystal structures clustering within ± 80 to ± 100 degrees compared to random 360-degree distribution without magnetic field. This alignment became progressively pronounced at higher doses, particularly at 8–16 Gy. Despite significant microstructural reorientation, optical density analysis revealed negligible dosimetric differences between magnetic field conditions, with variations remaining within experimental uncertainty. The findings indicate that magnetic fields influence topochemical polymerization directionality without affecting total polymerized material quantity, explaining why structural changes do not compromise dose measurement accuracy. These results resolve previous conflicting literature by demonstrating that EBT-3 RCFs maintain dosimetric reliability in magnetic field environments, supporting their continued use for accurate dose measurements in magnetic resonance-guided radiotherapy applications.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-22
DOI
https://doi.org/10.1038/s41598-026-56135-y
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Microstructural changes in radiochromic film and dosimetry in magnetic field

Michael Keidar, Vikas Soni, Indra J. Das
Scientific Reports
Advanced Radiotherapy Techniques
article

Microstructural changes in radiochromic film and dosimetry in magnetic field

Michael Keidar, Vikas Soni, Indra J. Das
article en

Abstract

Radiochromic film (RCF) dosimetry in magnetic resonance-guided linear accelerator systems requires validation due to conflicting reports regarding dosimetric accuracy in magnetic fields (MF). This study quantitatively evaluated microstructural changes and dosimetric response of EBT-3 RCFs exposed to ionizing radiation in a 0.35 T magnetic field. Films from a single batch were irradiated with 2, 5, 8, 10, and 16 Gy using a 6 MV flattening filter-free photon beam from a ViewRay magnetic resonance-linear accelerator unit, with and without magnetic field activation. Scanning electron microscopy (SEM) at 2500× magnification analyzed microstructural features, while quantitative measurements of needle-like crystal structures assessed length and angular orientation using ImageJ software. Optical density measurements employed standard RCF protocols with red-green-blue to grayscale conversion. Results demonstrated that crystal lengths remained consistent across all radiation doses regardless of magnetic field presence, with no statistically significant variations observed. However, magnetic field exposure produced dramatic angular alignment effects, with crystal structures clustering within ± 80 to ± 100 degrees compared to random 360-degree distribution without magnetic field. This alignment became progressively pronounced at higher doses, particularly at 8–16 Gy. Despite significant microstructural reorientation, optical density analysis revealed negligible dosimetric differences between magnetic field conditions, with variations remaining within experimental uncertainty. The findings indicate that magnetic fields influence topochemical polymerization directionality without affecting total polymerized material quantity, explaining why structural changes do not compromise dose measurement accuracy. These results resolve previous conflicting literature by demonstrating that EBT-3 RCFs maintain dosimetric reliability in magnetic field environments, supporting their continued use for accurate dose measurements in magnetic resonance-guided radiotherapy applications.

Scientific Reports
Northwestern University (US), George Washington University (US), Northwestern Memorial Hospital (US)
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon