Filtered high-energy X-ray generator as an alternative to cobalt-60 for total ionizing dose testing of electronics
Total Ionizing Dose testing of electronic components and systems has traditionally relied on the use of radioactive sources. Such sources raise safety and security concerns, creating a clear need for safer alternatives in industrial, medical, military, and research applications. In this work, a methodology for irradiating electronic components using filtered high-energy X-rays is evaluated, with the objective of preserving results comparable to those obtained using existing testing standards. Simulations are performed to select an appropriate X-ray filter capable of reproducing the degradation induced by 60 Co irradiation. A tin and copper filter is identified that attenuates low-energy photons while minimizing dose enhancement effects. Several irradiation conditions are investigated. The results demonstrate that irradiation with a high-energy X-ray generator using the tin and copper filter reproduces 60 Co degradation more closely than other filter configurations. A conversion factor is applied to compare component degradation at equivalent calculated doses in SiO 2 across the different irradiation conditions.
Authors
- Tadec Maraine
- J. Boch (ORCID: https://orcid.org/0000-0002-5660-7501)
- Julien Favrichon (ORCID: https://orcid.org/0000-0001-7586-1364)
- G. Carpentier
- F. Saigné
Institutions
- Centre National de la Recherche Scientifique (FR)
- Université de Montpellier (FR)
- Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR)
- Institut d'Électronique et des Systèmes (FR)
- CEA Marcoule (FR)
Publication Details
- Journal
- Microelectronic Engineering
- Published
- 2026-11-22
- DOI
- https://doi.org/10.1016/j.mee.2026.112563
- Primary Topic
- Radiation Effects in Electronics
- Type
- article
- Field-Weighted Citation Impact
- 0.00