Claim-specific evidence for reusing data-derived patient labels: a reporting survey and cross-database evaluation in sepsis

Background Patient labels derived from electronic health record data, including sepsis partitions, are stored and reused across studies and sites for risk stratification, assignment of new patients and treatment comparisons. Which stored objects and comparisons each use requires is seldom specified. We aimed to define the objects and comparisons needed to evaluate claims about reused patient labels and to assess how frequently they are reported. Methods We specified requirements for composition, discreteness, incremental information, external application and treatment comparison. We examined 54 sampled sepsis-partition reports and a K = 2 partition (K2) of 20,049 patients in the Medical Information Mart for Intensive Care (MIMIC)-IV database, assigned to 17,465 stays across 199 hospitals in the eICU Collaborative Research Database. Results K2 mainly recoded renal and acid-base physiology. It increased the mortality area under the curve by 0.050 over a limited clinical model but by < 0.001 over a model containing its source features. In post hoc external analyses, a fixed source-median imputation rule rendered the recovered assignment rule executable for new patients and reproduced 98.9% of the original MIMIC-IV labels; 9 of 199 hospitals lay outside 99.8% prevalence limits, and the mortality model with K2 had calibration slope 0.780. Intercept-and-slope updating in separate hospitals lowered its Brier score from 0.1219 to 0.1182 (difference − 0.0037, 95% CI -0.0055 to -0.0022); the model without K2 improved as well. Of the 54 reports surveyed, six evaluated incremental prediction, none against a comparator containing the clustering inputs, and none of 50 reports claiming distinct classes compared them with a continuous reference. Although allocation was reproducible, held-out shape evidence did not establish discrete classes. Renal replacement therapy after hour 24 failed prespecified support criteria in both groups; no effect was estimated. Conclusions Reuse of a patient label requires distinct evidence for assignment, predictive increment and risk-model transport. Archiving the label with its generating objects and reporting its version alongside the comparator makes these conclusions interpretable and identifies when adaptation or an alternative study design is required.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-22
DOI
https://doi.org/10.21203/rs.3.rs-11438034/v1
Primary Topic
Sepsis Diagnosis and Treatment
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Claim-specific evidence for reusing data-derived patient labels: a reporting survey and cross-database evaluation in sepsis

范春蕾, Shouhua Zang, Xiaomin Wu, 张玉坤 et al.
Research Square
Sepsis Diagnosis and Treatment
preprint

Claim-specific evidence for reusing data-derived patient labels: a reporting survey and cross-database evaluation in sepsis

范春蕾, Shouhua Zang, Xiaomin Wu, 张玉坤, Jin Xie, Jun Chen, Tianyi Wang
preprint en

Abstract

Background Patient labels derived from electronic health record data, including sepsis partitions, are stored and reused across studies and sites for risk stratification, assignment of new patients and treatment comparisons. Which stored objects and comparisons each use requires is seldom specified. We aimed to define the objects and comparisons needed to evaluate claims about reused patient labels and to assess how frequently they are reported. Methods We specified requirements for composition, discreteness, incremental information, external application and treatment comparison. We examined 54 sampled sepsis-partition reports and a K = 2 partition (K2) of 20,049 patients in the Medical Information Mart for Intensive Care (MIMIC)-IV database, assigned to 17,465 stays across 199 hospitals in the eICU Collaborative Research Database. Results K2 mainly recoded renal and acid-base physiology. It increased the mortality area under the curve by 0.050 over a limited clinical model but by < 0.001 over a model containing its source features. In post hoc external analyses, a fixed source-median imputation rule rendered the recovered assignment rule executable for new patients and reproduced 98.9% of the original MIMIC-IV labels; 9 of 199 hospitals lay outside 99.8% prevalence limits, and the mortality model with K2 had calibration slope 0.780. Intercept-and-slope updating in separate hospitals lowered its Brier score from 0.1219 to 0.1182 (difference − 0.0037, 95% CI -0.0055 to -0.0022); the model without K2 improved as well. Of the 54 reports surveyed, six evaluated incremental prediction, none against a comparator containing the clustering inputs, and none of 50 reports claiming distinct classes compared them with a continuous reference. Although allocation was reproducible, held-out shape evidence did not establish discrete classes. Renal replacement therapy after hour 24 failed prespecified support criteria in both groups; no effect was estimated. Conclusions Reuse of a patient label requires distinct evidence for assignment, predictive increment and risk-model transport. Archiving the label with its generating objects and reporting its version alongside the comparator makes these conclusions interpretable and identifies when adaptation or an alternative study design is required.

Research Square
First Affiliated Hospital of Soochow University (CN)
Sepsis Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon