Dataset-dependent patient-overlap bias in breast thermography deep learning
Deep learning studies in breast thermography frequently report near-perfect diagnostic performance (AUC > 0.99), yet evaluation protocols do not always explicitly account for data leakage caused by patient overlap. Although patient-level leakage is well documented in other imaging modalities, the magnitude of performance inflation and its modulation by dataset structure remain insufficiently quantified in breast thermography. We conducted a cross-dataset evaluation using two public breast thermography datasets with contrasting overlap characteristics: DMR-IR (5,444 images, 214 patients, Jaccard index $$J=0.972$$ ) and Mendeley (357 images, 119 patients, $$J=0.467$$ ). Across four architectures spanning CNN and vision transformer families, we contrasted image-level partitioning with patient-level partitioning ( $$J=0$$ ) and quantified performance differentials ( $$\Delta _{\text {AUC}}$$ ) using Nadeau-Bengio corrected inference. In DMR-IR, image-level partitioning produced near-perfect performance similar to levels commonly reported in the literature (mean AUC 0.999), whereas performance decreased to 0.951 under strict patient-level isolation ( $$\Delta _{\text {AUC}}=+4.8\%$$ ). Mendeley showed a 2.6-fold greater inflation magnitude despite lower measured overlap, with mean AUC decreasing from 0.888 to 0.762 ( $$\Delta _{\text {AUC}}=+12.6\%$$ ). Controlled intra-dataset manipulation further suggested a non-linear relationship between patient overlap and performance inflation, with apparent performance increasing rapidly even under partial leakage conditions. Lightweight models showed larger inflation in this experimental setting. Physics-based radiometric preprocessing using a $$T^4$$ transformation provided modest benefit under patient-level validation but did not remove the dataset-dependent inflation gap. These findings do not invalidate previously reported strong thermography results; rather, they indicate that reports of near-perfect performance should be interpreted with appropriate caution when strict patient-level separation is not clearly documented.
Authors
- A. K. M. Muzahidul Islam (ORCID: https://orcid.org/0000-0002-2349-1610)
- Fahmid Al Farid (ORCID: https://orcid.org/0000-0003-2625-2348)
- Md. Mahfuzul Haque (ORCID: https://orcid.org/0000-0003-2769-2265)
- Hezerul Bin Abdul Karim (ORCID: https://orcid.org/0000-0002-7613-4596)
- Iftekhar Ahmed (ORCID: https://orcid.org/0000-0001-8221-5352)
- Md Zahidul Islam (ORCID: https://orcid.org/0000-0002-4868-4945)
- Jia Uddin (ORCID: https://orcid.org/0000-0002-3403-4095)
- M. A. Awal
- Nazmul Huda
- Ishtiak Al Mamoon
- Md Abdul Khalid Sondo
Institutions
- Multimedia University (MY)
- International University of Business Agriculture and Technology (BD)
- Berlin School of Business and Innovation GmbH (DE)
- United International University (BD)
- Woosong University (KR)
Publication Details
- Journal
- Scientific Reports
- Published
- 2026-11-23
- DOI
- https://doi.org/10.1038/s41598-026-64646-x
- Primary Topic
- Infrared Thermography in Medicine
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Multimedia University
- United International University