Clinical evaluation of modified bite-on-bite cholangioscopy-guided biopsy for indeterminate biliary strictures

Background: Peroral cholangioscopy (POCS)-guided biopsy is limited by small forceps and superficial sampling. We evaluated tissue acquisition using a modified bite-on-bite (mBOB) technique for indeterminate biliary strictures. Methods: In this single-center retrospective study, 133 patients underwent mBOB or conventional POCS-guided biopsy. An expert gastrointestinal pathologist reviewed all 208 retrieved specimens while blinded to biopsy technique. Histologically non-evaluable specimens were counted as unsuccessful stromal acquisitions without assigning a stromal score. The primary endpoint was score ≥2 stromal acquisition per retrieved specimen. Results: Among 133 patients (63 mBOB, 70 conventional), 208 specimens were retrieved (99 and 109, respectively). Documented score ≥2 stromal yield per all retrieved specimens was 86/99 (86.9%) versus 57/109 (52.3%), respectively. Operator-adjusted, patient-clustered generalized estimating equations (GEE) showed an odds ratio (OR) of 7.11 (95% confidence interval [CI] 3.32–15.25; P < 0.001). Adequate tissue acquisition was 91/99 (91.9%) versus 86/109 (78.9%; adjusted OR 3.14, 95% CI 1.23–7.97; P = 0.016). Among adequate specimens, score ≥2 stroma was observed in 86/91 (94.5%) versus 57/86 (66.3%; adjusted OR 12.51, 95% CI 4.34–36.04). Mean largest-fragment area was 1.04 versus 0.81 mm² (operator-adjusted mean difference 0.214 mm²; P = 0.085). Adverse events occurred in three patients per group. Conclusions: mBOB was associated with a higher rate of documented fibrous stromal acquisition per retrieved specimen and greater histological adequacy. The non-randomized design and different bites per pass limit causal interpretation. Diagnostic superiority and equivalent safety remain unproven.

Authors

Institutions

Publication Details

Journal
Endoscopy International Open
Published
2026-11-22
DOI
https://doi.org/10.1055/a-3008-4283
Primary Topic
Gallbladder and Bile Duct Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Clinical evaluation of modified bite-on-bite cholangioscopy-guided biopsy for indeterminate biliary strictures

Kimi Bessho, 三記 石田, Hiroki Nishikawa, Yoshinobu Hirose et al.
Endoscopy International Open
Gallbladder and Bile Duct Disorders
article

Clinical evaluation of modified bite-on-bite cholangioscopy-guided biopsy for indeterminate biliary strictures

Kimi Bessho, 三記 石田, Hiroki Nishikawa, Yoshinobu Hirose, Nobuhiro Hattori, Takafumi Kanadani, Junichi Nakamura, Takeshi Ogura, Yoshitaro Yamamoto, Saori Ueno, Nobu Nishioka, Kentaro Osaka
article en

Abstract

Background: Peroral cholangioscopy (POCS)-guided biopsy is limited by small forceps and superficial sampling. We evaluated tissue acquisition using a modified bite-on-bite (mBOB) technique for indeterminate biliary strictures. Methods: In this single-center retrospective study, 133 patients underwent mBOB or conventional POCS-guided biopsy. An expert gastrointestinal pathologist reviewed all 208 retrieved specimens while blinded to biopsy technique. Histologically non-evaluable specimens were counted as unsuccessful stromal acquisitions without assigning a stromal score. The primary endpoint was score ≥2 stromal acquisition per retrieved specimen. Results: Among 133 patients (63 mBOB, 70 conventional), 208 specimens were retrieved (99 and 109, respectively). Documented score ≥2 stromal yield per all retrieved specimens was 86/99 (86.9%) versus 57/109 (52.3%), respectively. Operator-adjusted, patient-clustered generalized estimating equations (GEE) showed an odds ratio (OR) of 7.11 (95% confidence interval [CI] 3.32–15.25; P < 0.001). Adequate tissue acquisition was 91/99 (91.9%) versus 86/109 (78.9%; adjusted OR 3.14, 95% CI 1.23–7.97; P = 0.016). Among adequate specimens, score ≥2 stroma was observed in 86/91 (94.5%) versus 57/86 (66.3%; adjusted OR 12.51, 95% CI 4.34–36.04). Mean largest-fragment area was 1.04 versus 0.81 mm² (operator-adjusted mean difference 0.214 mm²; P = 0.085). Adverse events occurred in three patients per group. Conclusions: mBOB was associated with a higher rate of documented fibrous stromal acquisition per retrieved specimen and greater histological adequacy. The non-randomized design and different bites per pass limit causal interpretation. Diagnostic superiority and equivalent safety remain unproven.

Endoscopy International Open
Osaka Medical and Pharmaceutical University (JP), Osaka Medical and Pharmaceutical University Hospital (JP)
Gallbladder and Bile Duct Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon