ANÁLISE ANALÍTICO-EXPERIMENTAL DAS PROPRIEDADES MECÂNICAS E DETERMINAÇÃO DO TORQUE DE APERTO ADMISSÍVEL EM UNIÕES PARAFUSADAS INDUSTRIAIS

This work presents an analytical model, implemented in a spreadsheet, to estimate the allowable tightening torque in industrial bolted joints, accounting for fastener geometry, friction, and mechanical properties. Hardness and tensile tests were conducted to characterize the bolts and compare them with regulatory requirements. For an M36 × 1.50, class 8.8 bolt, the estimated torque was 1,596.42 N·m—corresponding to a preload of 513.88 kN—with a safety factor of 1.2. For the two samples subjected to tensile testing, the strength estimates derived from hardness conversions differed by less than 0.25% from the experimental values. The study demonstrates a preliminary application of the tool; validation will require specific tightening tests.

Authors

Institutions

Publication Details

Journal
Anais do Congresso Brasileiro de Iniciação Científica
Published
2026-11-22
DOI
https://doi.org/10.66221/vvc0ct65
Primary Topic
Engineering Structural Analysis Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

ANÁLISE ANALÍTICO-EXPERIMENTAL DAS PROPRIEDADES MECÂNICAS E DETERMINAÇÃO DO TORQUE DE APERTO ADMISSÍVEL EM UNIÕES PARAFUSADAS INDUSTRIAIS

Pedro Gomes, Caroline Oliveira, João Almeida, Willy Moraes et al.
Anais do Congresso Brasileiro de Iniciação Científica
Engineering Structural Analysis Methods
article

ANÁLISE ANALÍTICO-EXPERIMENTAL DAS PROPRIEDADES MECÂNICAS E DETERMINAÇÃO DO TORQUE DE APERTO ADMISSÍVEL EM UNIÕES PARAFUSADAS INDUSTRIAIS

Pedro Gomes, Caroline Oliveira, João Almeida, Willy Moraes, Gustavo Terceiro
article en

Abstract

This work presents an analytical model, implemented in a spreadsheet, to estimate the allowable tightening torque in industrial bolted joints, accounting for fastener geometry, friction, and mechanical properties. Hardness and tensile tests were conducted to characterize the bolts and compare them with regulatory requirements. For an M36 × 1.50, class 8.8 bolt, the estimated torque was 1,596.42 N·m—corresponding to a preload of 513.88 kN—with a safety factor of 1.2. For the two samples subjected to tensile testing, the strength estimates derived from hardness conversions differed by less than 0.25% from the experimental values. The study demonstrates a preliminary application of the tool; validation will require specific tightening tests.

Anais do Congresso Brasileiro de Iniciação CientíficaVol. 3(1)
Universidade Santa Cecília (BR)
Engineering Structural Analysis Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon