TransAct: efficient attention-based temporal modelling for real-time wearable human activity recognition
Wearable sensors have made Human Activity Recognition (HAR) via intelligent healthcare and assisted living systems very efficient by enabling the quick processing of multivariate time-series streams of data. We propose a novel framework known as TransAct that utilizes a Transformer-based architecture for the computationally efficient temporal modeling of wearable sensor signals. TransAct is designed to capture long-range dependencies among sensor-derived features by leveraging optimized input projection, learnable positional encodings, and multi-headed self-attention mechanisms. We construct a hybrid CNN-LSTM architecture as a matched comparator, applying identical preprocessing and training configuration to both models, and evaluate both across five independent random seeds on three public benchmarks: UCI HAR, PAMAP2, and OPPORTUNITY. On UCI HAR, TransAct shows a higher held-out test accuracy than the CNN-LSTM baseline ( \(95.10\% \pm 0.37\%\) vs. \(94.26\% \pm 0.55\%\) ), a borderline-significant advantage by a paired t -test ( \(p=0.050\) ) that does not reach significance under the non-parametric Wilcoxon signed-rank test ( \(p=0.125\) ). On PAMAP2, where the input is genuine chronologically-ordered raw inertial signal rather than UCI HAR’s reshaped engineered-feature vector, the advantage is larger and more clearly significant ( \(86.13\% \pm 0.68\%\) vs. \(82.75\% \pm 1.70\%\) ; \(p=0.012\) ). On OPPORTUNITY, a severely class-imbalanced 18-class gesture-recognition benchmark, overall accuracy is statistically indistinguishable between the two models ( \(88.48\% \pm 3.54\%\) vs. \(89.01\% \pm 2.64\%\) ; \(p=0.452\) ), but TransAct achieves significantly higher macro-F1 ( \(54.15\% \pm 9.17\%\) vs. \(51.55\% \pm 9.04\%\) ; \(p=0.030\) ), the more informative metric under severe class imbalance since it does not let performance on the dominant “Null” class dominate the score. A multi-seed ablation study on UCI HAR finds no statistically detectable contribution from any of the three architectural components tested individually – positional encoding, multi-head (vs. single-head) attention, and layer normalization all leave accuracy statistically indistinguishable from the full model ( \(p>0.9\) in every case). TransAct is consistently and significantly slower than the CNN-LSTM baseline across all three datasets: on a T4 GPU, mean epoch time and per-sample inference latency are both roughly 2–3 \(\times\) higher for TransAct than for CNN-LSTM ( \(p<0.0001\) throughout), consistent with TransAct’s larger parameter count. Taken together, these results support a specific and dataset-dependent conclusion: attention-based modeling of engineered or raw wearable-sensor sequences yields a real, reproducible accuracy or macro-F1 advantage over a matched recurrent baseline on two of the three benchmarks tested, most clearly on genuine time-series input, but this advantage is not universal (it does not appear in OPPORTUNITY’s overall accuracy), and it always comes at a genuine, non-trivial, and consistent computational cost. We report these results, including the null and negative findings, alongside the accuracy gains, and discuss what remains to be established (probability-calibrated discrimination curves, a resolved discrepancy in our OPPORTUNITY channel count, and a mechanistic account of the ablation null results) before broader claims of efficiency or component-level necessity can be supported.
Authors
- Anusha Nalajala (ORCID: https://orcid.org/0000-0002-1167-6343)
- Bhavya Raja Gopal Yarlagadda (ORCID: https://orcid.org/0000-0003-1860-7882)
- Arjun Pramod
- Inturi Anitha Rani
- Sirivella Rajesh
Institutions
- Medical University of South Carolina (US)
- SRM University, Andhra Pradesh (IN)
Publication Details
- Journal
- Scientific Reports
- Published
- 2026-11-22
- DOI
- https://doi.org/10.1038/s41598-026-80279-6
- Primary Topic
- Context-Aware Activity Recognition Systems
- Type
- article
- Field-Weighted Citation Impact
- 0.00