Dynamic load matching in high-temperature heat pump vacuum contact drying of kitchen waste: Experimental investigation and performance assessment

Batch drying of high-moisture kitchen waste is characterized by a continuously declining thermal load, which can lead to heat-supply mismatch, frequent compressor cycling, and deteriorated energy performance in fixed-capacity heat pump systems. To address this issue, an adaptive high-temperature heat pump vacuum contact drying (AHPVCD) system was developed by integrating two parallel heat pump units with different capacities, stepwise capacity regulation, vapor heat recovery, and inter-batch thermal storage. A pilot-scale experiment was conducted using 750 kg of kitchen waste with an average initial moisture content of 83.0% on a wet basis. Compared with a fixed-capacity single-unit heat pump drying system, the proposed staged operating strategy effectively suppressed compressor cycling and provided a smoother heat-transfer-fluid temperature response as the drying load declined. During the main drying period, the heat-pump COP and system COP were maintained at approximately 4.0-4.6 and 3.2-3.6, respectively, while the interval SMER reached a maximum of 4.85 kg/kWh and the batch-average SMER was approximately 3.45 kg/kWh. Approximately 90% of the thermal energy carried by the generated vapor was recovered through the evaporators, and an additional 25.7 kWh was stored for subsequent batch preheating. Reuse of the stored heat reduced the specific preheating electricity consumption from approximately 45 to 28 kWh/t. The full-batch electricity consumption was 174.57 kWh, corresponding to 232.8 kWh/t of treated kitchen waste. Exergy analysis further showed that the dryer exergy efficiency decreased from 62.3% to 47.2% as drying progressed, indicating increasingly significant heat- and mass-transfer irreversibility during the later drying stage. The proposed system also achieved a unit treatment cost of CNY 151.3/t and a 15-year TEWI of 364.93 tCO₂. These results demonstrate that staged capacity regulation combined with vapor heat recovery can improve heat-supply–demand matching and overall performance in batch drying processes with strongly time-varying thermal loads.

Authors

Publication Details

Journal
Figshare
Published
2026-11-22
DOI
https://doi.org/10.6084/m9.figshare.35084160
Primary Topic
Food Drying and Modeling
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Dynamic load matching in high-temperature heat pump vacuum contact drying of kitchen waste: Experimental investigation and performance assessment

Benliu Zhou, Chang Xu, Hongting Ma, Xin Xu et al.
Figshare
Food Drying and Modeling
article

Dynamic load matching in high-temperature heat pump vacuum contact drying of kitchen waste: Experimental investigation and performance assessment

Benliu Zhou, Chang Xu, Hongting Ma, Xin Xu, Suo Wang
article en

Abstract

Batch drying of high-moisture kitchen waste is characterized by a continuously declining thermal load, which can lead to heat-supply mismatch, frequent compressor cycling, and deteriorated energy performance in fixed-capacity heat pump systems. To address this issue, an adaptive high-temperature heat pump vacuum contact drying (AHPVCD) system was developed by integrating two parallel heat pump units with different capacities, stepwise capacity regulation, vapor heat recovery, and inter-batch thermal storage. A pilot-scale experiment was conducted using 750 kg of kitchen waste with an average initial moisture content of 83.0% on a wet basis. Compared with a fixed-capacity single-unit heat pump drying system, the proposed staged operating strategy effectively suppressed compressor cycling and provided a smoother heat-transfer-fluid temperature response as the drying load declined. During the main drying period, the heat-pump COP and system COP were maintained at approximately 4.0-4.6 and 3.2-3.6, respectively, while the interval SMER reached a maximum of 4.85 kg/kWh and the batch-average SMER was approximately 3.45 kg/kWh. Approximately 90% of the thermal energy carried by the generated vapor was recovered through the evaporators, and an additional 25.7 kWh was stored for subsequent batch preheating. Reuse of the stored heat reduced the specific preheating electricity consumption from approximately 45 to 28 kWh/t. The full-batch electricity consumption was 174.57 kWh, corresponding to 232.8 kWh/t of treated kitchen waste. Exergy analysis further showed that the dryer exergy efficiency decreased from 62.3% to 47.2% as drying progressed, indicating increasingly significant heat- and mass-transfer irreversibility during the later drying stage. The proposed system also achieved a unit treatment cost of CNY 151.3/t and a 15-year TEWI of 364.93 tCO₂. These results demonstrate that staged capacity regulation combined with vapor heat recovery can improve heat-supply–demand matching and overall performance in batch drying processes with strongly time-varying thermal loads.

Figshare
Food Drying and Modeling
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Dynamic load matching in high-temperature heat pump vacuum contact drying of kitchen waste: Experimental investigation and performance assessment — Benliu Zhou, Chang Xu, et al. · Figshare (2026) | TGRS Research Map | TGRS