Artificial Intelligence-Assisted Optical Diagnosis Does Not Improve Colorectal Polyp Characterization: A Pooled Analysis of Two Randomized Trials

Background and study aims Computer-aided diagnosis (CADx) is intended to improve real-time characterization of colorectal polyps. This study evaluates whether CADx-assisted colonoscopy improves the accuracy of polyp classification compared with conventional colonoscopy (CC). Patients and methods We pooled CADx-relevant data from two randomized trials evaluating CAD EYE and GI Genius. Participants were randomized 1:1 to CADx-assisted colonoscopy or conventional colonoscopy, with no AI active at any stage in the control group. The primary outcome was per-polyp accuracy of the endoscopist’s optical diagnosis against histopathology. Results 684 patients with 1,154 lesion records were included, 795 lesions (451 CADx-assisted, 344 CC) entering the primary analysis. Overall accuracy did not differ between CADx-assisted endoscopy and CC (76.9%, 95% CI 72.8–80.6 vs 79.7%, 75.1–83.6). CC showed higher sensitivity than CADx-assisted endoscopy (88.9%, 84.2–92.3 vs 80.6%, 75.9–84.6; adjusted odds ratio 0.50, 0.28–0.91), with a similar trend for negative predictive value (NPV) (71.7% vs 58.9%). The sensitivity difference was confined to experienced and expert endoscopists (89.4% vs 80.2%) and absent among trainees and newly qualified specialists (p for interaction 0.248). For 0–4 mm polyps, NPV was 71.4% with CC and 54.2% with CADx; for 0–4 mm rectosigmoid lesions, the population to which the guideline threshold applies, it was 92.9% and 66.7%. At least one adenoma was optically classified as non-neoplastic in 25.9% of CADx participants versus 13.0% of CC participants (p=0.003). Conclusions CADx assistance did not improve polyp characterization, and sensitivity for adenomatous lesions was lower when a prediction was displayed. These findings indicate that CADx requires refinement before it can support optical management.

Authors

Institutions

Publication Details

Journal
Endoscopy International Open
Published
2026-11-22
DOI
https://doi.org/10.1055/a-3011-6534
Primary Topic
Colorectal Cancer Screening and Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Artificial Intelligence-Assisted Optical Diagnosis Does Not Improve Colorectal Polyp Characterization: A Pooled Analysis of Two Randomized Trials

Hugo L. Hammer, Nikolaos Papachrysos, Björn Lindkvist, Jonas Varkey et al.
Endoscopy International Open
Colorectal Cancer Screening and Detection
article

Artificial Intelligence-Assisted Optical Diagnosis Does Not Improve Colorectal Polyp Characterization: A Pooled Analysis of Two Randomized Trials

Hugo L. Hammer, Nikolaos Papachrysos, Björn Lindkvist, Jonas Varkey, Per Hedenström, A Eriksson, Thomas de Lange, Jonny Trinh, Stephanie Barth, Linda Krona, Rasmus Söderström Sondén, Bente Rauch, Michael Köster
article en

Abstract

Background and study aims Computer-aided diagnosis (CADx) is intended to improve real-time characterization of colorectal polyps. This study evaluates whether CADx-assisted colonoscopy improves the accuracy of polyp classification compared with conventional colonoscopy (CC). Patients and methods We pooled CADx-relevant data from two randomized trials evaluating CAD EYE and GI Genius. Participants were randomized 1:1 to CADx-assisted colonoscopy or conventional colonoscopy, with no AI active at any stage in the control group. The primary outcome was per-polyp accuracy of the endoscopist’s optical diagnosis against histopathology. Results 684 patients with 1,154 lesion records were included, 795 lesions (451 CADx-assisted, 344 CC) entering the primary analysis. Overall accuracy did not differ between CADx-assisted endoscopy and CC (76.9%, 95% CI 72.8–80.6 vs 79.7%, 75.1–83.6). CC showed higher sensitivity than CADx-assisted endoscopy (88.9%, 84.2–92.3 vs 80.6%, 75.9–84.6; adjusted odds ratio 0.50, 0.28–0.91), with a similar trend for negative predictive value (NPV) (71.7% vs 58.9%). The sensitivity difference was confined to experienced and expert endoscopists (89.4% vs 80.2%) and absent among trainees and newly qualified specialists (p for interaction 0.248). For 0–4 mm polyps, NPV was 71.4% with CC and 54.2% with CADx; for 0–4 mm rectosigmoid lesions, the population to which the guideline threshold applies, it was 92.9% and 66.7%. At least one adenoma was optically classified as non-neoplastic in 25.9% of CADx participants versus 13.0% of CC participants (p=0.003). Conclusions CADx assistance did not improve polyp characterization, and sensitivity for adenomatous lesions was lower when a prediction was displayed. These findings indicate that CADx requires refinement before it can support optical management.

Endoscopy International Open
OsloMet – Oslo Metropolitan University (NO), Sahlgrenska University Hospital (SE), Göteborgs Stads (SE), Skaraborg Hospital (SE), Angered Hospital (SE), Simula Metropolitan Center for Digital Engineering (NO), Sjukhuset i Lidköping (SE), University of Gothenburg (SE)
Colorectal Cancer Screening and Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon