From voxel S-values to DNA damage: Multiscale simulation of β− emitters with Geant4 and Geant4-DNA

Purpose: The present study investigates dosimetric profiles and radiation-induced DNA damage for several therapeutic β − emitters, with particular emphasis on 111 Ag , 47 Sc , and 161 Tb in the framework of the ISOLPHARM project. Methods: Monte Carlo simulations are performed using the Geant4 toolkit and its extension Geant4-DNA. Macroscopic dosimetry is studied in voxelized and spherical geometries. Concerning the DNA damage evaluation, the same DNA geometries, physicochemical stage, and damage scoring criteria as those in the literature pertaining to the Geant4-DNA project are adopted to ensure direct comparability. Electron spectra from 47 Sc , 90 Y , 111 Ag , 131 I , 153 Sm , 161 Tb , 177 Lu , and 186 Re are sampled, taking into account both β − and Auger radiation. Results: A database including voxel S-values and dose point kernels for each medical β − emitter has been computed. DNA damage data for the same nuclides, in terms of single- and double-strand breaks, have been simulated with the Geant4-DNA libraries. Results are similar for almost all radionuclides, probably because of the higher weight of indirect DNA damage rather than direct. Conclusions: The innovative radionuclides 111 Ag , 161 Tb , and 47 Sc behave very similarly to radionuclides already applied in nuclear medicine. For this reason, the preclinical development of radiopharmaceuticals labeled with these radioactive agents should be kept under observation in the near future.

Authors

Institutions

Publication Details

Journal
Physica Medica
Published
2026-11-22
DOI
https://doi.org/10.1016/j.ejmp.2026.107230
Primary Topic
Radiopharmaceutical Chemistry and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

From voxel S-values to DNA damage: Multiscale simulation of β− emitters with Geant4 and Geant4-DNA

Giulia Valli, Davide Serafini, Antonietta Donzella, S. Corradetti et al.
Physica Medica
Radiopharmaceutical Chemistry and Applications
article

From voxel S-values to DNA damage: Multiscale simulation of β− emitters with Geant4 and Geant4-DNA

Giulia Valli, Davide Serafini, Antonietta Donzella, S. Corradetti, M. Lunardon, A. Andrighetto, Silva Bortolussi, E. Mariotti, Alberto Arzenton, Luigi Zangrando, Aurora Leso
article en

Abstract

Purpose: The present study investigates dosimetric profiles and radiation-induced DNA damage for several therapeutic β − emitters, with particular emphasis on 111 Ag , 47 Sc , and 161 Tb in the framework of the ISOLPHARM project. Methods: Monte Carlo simulations are performed using the Geant4 toolkit and its extension Geant4-DNA. Macroscopic dosimetry is studied in voxelized and spherical geometries. Concerning the DNA damage evaluation, the same DNA geometries, physicochemical stage, and damage scoring criteria as those in the literature pertaining to the Geant4-DNA project are adopted to ensure direct comparability. Electron spectra from 47 Sc , 90 Y , 111 Ag , 131 I , 153 Sm , 161 Tb , 177 Lu , and 186 Re are sampled, taking into account both β − and Auger radiation. Results: A database including voxel S-values and dose point kernels for each medical β − emitter has been computed. DNA damage data for the same nuclides, in terms of single- and double-strand breaks, have been simulated with the Geant4-DNA libraries. Results are similar for almost all radionuclides, probably because of the higher weight of indirect DNA damage rather than direct. Conclusions: The innovative radionuclides 111 Ag , 161 Tb , and 47 Sc behave very similarly to radionuclides already applied in nuclear medicine. For this reason, the preclinical development of radiopharmaceuticals labeled with these radioactive agents should be kept under observation in the near future.

Physica MedicaVol. 152
University of Siena (IT), University of Padua (IT), Istituto Nazionale di Fisica Nucleare (IT), University of Ferrara (IT), University of Pavia (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Pavia (IT), Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Pisa (IT), University of Brescia (IT)
Radiopharmaceutical Chemistry and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon