Incremental prognostic value of early arterial blood gases at ICU reassessment in adults with hypercapnia: a development and external validation study

Background Arterial blood gases are routinely repeated to monitor therapeutic response in critically ill patients with hypercapnia. However, whether initial acid-base history retains incremental prognostic value once contemporary clinical status and reassessment blood gases are known remains unclear. We evaluated whether early pH and PaCO₂ improve in-hospital mortality prediction beyond current physiological information at predefined ICU reassessment landmarks. Methods We developed models in MIMIC-IV 3.1 and evaluated frozen predictions in eICU 2.0. Adults had PaCO₂ >45 mmHg in their first eligible paired arterial blood gas within 6 hours of ICU admission. The primary 24-hour landmark required survival, continued ICU stay and an 18–24-hour repeat. Five algorithm families were compared using patient-grouped nested cross-validation. The current-information model (L) and history-augmented model (H) received 11 clinical inputs and the latest pH/PaCO₂; H also received the first pH/PaCO₂. The primary difference was Brier(L)−Brier(H), with hospital–patient product-weight confidence intervals. Secondary analyses examined 12-hour reassessment and a 24-hour fallback workflow. Results Development included 2662 admissions with 561 deaths; external evaluation included 2506 admissions with 577 deaths across 154 hospitals. External H/L Brier scores were 0.1476/0.1478 and AUCs 0.7545/0.7536. The paired Brier difference was 0.27 × 10⁻³ (95% CI − 1.10 × 10⁻³ to 1.69 × 10⁻³). Calibration slopes were 0.880/0.882. The 12-hour difference was 0.75 × 10⁻³ (95% CI − 1.78 × 10⁻³ to 3.51 × 10⁻³). The external workflow used H in 23.06% of 10865 admissions and yielded a Brier difference of − 0.12 × 10⁻³ (95% CI − 2.17 × 10⁻³ to 1.90 × 10⁻³). SHAP attributed greater average importance to current pH and clinical status than to early gas values. Browser calculations were verified against the Python implementation. Conclusions Early blood gas history provided an uncertain predictive increment after contemporary reassessment. Repeat measurement coverage and external calibration constrain application of these landmark models. The verified browser implementation supports research inspection of the frozen predictions.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-22
DOI
https://doi.org/10.21203/rs.3.rs-11318566/v1
Primary Topic
Sepsis Diagnosis and Treatment
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Incremental prognostic value of early arterial blood gases at ICU reassessment in adults with hypercapnia: a development and external validation study

Cai Xinrui, Jitao Xu, Peng Li, Weibin Qian et al.
Research Square
Sepsis Diagnosis and Treatment
preprint

Incremental prognostic value of early arterial blood gases at ICU reassessment in adults with hypercapnia: a development and external validation study

Cai Xinrui, Jitao Xu, Peng Li, Weibin Qian, Xitong Liang
preprint en

Abstract

Background Arterial blood gases are routinely repeated to monitor therapeutic response in critically ill patients with hypercapnia. However, whether initial acid-base history retains incremental prognostic value once contemporary clinical status and reassessment blood gases are known remains unclear. We evaluated whether early pH and PaCO₂ improve in-hospital mortality prediction beyond current physiological information at predefined ICU reassessment landmarks. Methods We developed models in MIMIC-IV 3.1 and evaluated frozen predictions in eICU 2.0. Adults had PaCO₂ >45 mmHg in their first eligible paired arterial blood gas within 6 hours of ICU admission. The primary 24-hour landmark required survival, continued ICU stay and an 18–24-hour repeat. Five algorithm families were compared using patient-grouped nested cross-validation. The current-information model (L) and history-augmented model (H) received 11 clinical inputs and the latest pH/PaCO₂; H also received the first pH/PaCO₂. The primary difference was Brier(L)−Brier(H), with hospital–patient product-weight confidence intervals. Secondary analyses examined 12-hour reassessment and a 24-hour fallback workflow. Results Development included 2662 admissions with 561 deaths; external evaluation included 2506 admissions with 577 deaths across 154 hospitals. External H/L Brier scores were 0.1476/0.1478 and AUCs 0.7545/0.7536. The paired Brier difference was 0.27 × 10⁻³ (95% CI − 1.10 × 10⁻³ to 1.69 × 10⁻³). Calibration slopes were 0.880/0.882. The 12-hour difference was 0.75 × 10⁻³ (95% CI − 1.78 × 10⁻³ to 3.51 × 10⁻³). The external workflow used H in 23.06% of 10865 admissions and yielded a Brier difference of − 0.12 × 10⁻³ (95% CI − 2.17 × 10⁻³ to 1.90 × 10⁻³). SHAP attributed greater average importance to current pH and clinical status than to early gas values. Browser calculations were verified against the Python implementation. Conclusions Early blood gas history provided an uncertain predictive increment after contemporary reassessment. Repeat measurement coverage and external calibration constrain application of these landmark models. The verified browser implementation supports research inspection of the frozen predictions.

Research Square
Shandong University of Traditional Chinese Medicine (CN), Affiliated Hospital of Shandong University of Traditional Chinese Medicine (CN), Shandong First Medical University (CN)
Sepsis Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon