Four‐Screw Versus Two‐Screw Zero‐Profile Implants: Effects on Overloaded Vertebral Body Following Anterior Cervical Discectomy and Fusion
Objective Although zero‐profile implants with different screw configurations are increasingly used in anterior cervical discectomy and fusion (ACDF), whether four‐screw and two‐screw designs differentially affect the overloaded vertebral body (OVB) remains unknown. This study aimed to compare the effects of four‐screw and two‐screw zero‐profile implants on radiological outcomes of the OVB and clinical outcomes after two‐level ACDF, and to provide a reference for further investigation and prevention of OVB deformation. Methods This retrospective study analyzed 209 patients who underwent two‐level ACDF between April 2012 and May 2023. Radiographic parameters included anterior vertebral height (AH), posterior vertebral height (PH), cross‐sectional area (CSA), wedge angle (WA), wedge ratio (WR), cervical lordosis (CL), and surgical segment angle (SSA). Clinical outcomes were evaluated using the modified Japanese Orthopedic Association (mJOA) score, neck disability index (NDI) score, and visual analog scale (VAS) score for neck and arm pain. Surgical safety was evaluated based on the incidence of complications during the follow‐up period. Results The deformities of OVB in both groups primarily presented as the reduction in AH and WR. The four‐screw group exhibited less deformation compared to the two‐screw group. At 3 months, 6 months, 12 months, and the final follow‐up, the AH and WR of OVB in the two‐screw group were significantly lower than those in the four‐screw group ( p < 0.05). Similarly, at 6 months, 12 months, and the final follow‐up, the CSA of OVB was significantly lower, and the WA showed a significantly greater magnitude of kyphotic change in the two‐screw group compared to the four‐screw group ( p < 0.05). By 12 months postoperatively, OVB in the two‐screw group was in mild deformation. Compared with the four‐screw group, the two‐screw group demonstrated a greater loss of cervical lordosis at the final follow‐up ( p < 0.05). Although both groups showed significant clinical improvement from the preoperative baseline, a statistically significant difference in VAS scores of the neck was observed between the two groups at the final follow‐up ( p < 0.05). Conclusions Our study showed that comparable clinical outcomes can be achieved in two‐level ACDF using either four‐screw or two‐screw zero‐profile implants. However, the four‐screw implant showed superior performance in preventing and delaying postoperative deformation of OVB compared to the two‐screw implant, which is crucial for sustaining cervical sagittal balance and improving long‐term clinical outcomes.
Authors
- Shihao Chen (ORCID: https://orcid.org/0000-0002-9123-0375)
- Leilei Tian (ORCID: https://orcid.org/0000-0001-6695-4614)
- Minghe Yao (ORCID: https://orcid.org/0000-0003-2558-5829)
- Xiao Yang (ORCID: https://orcid.org/0009-0006-6826-8961)
- Hao Liu (ORCID: https://orcid.org/0000-0002-2992-6232)
- Xiaoqiang Zhao (ORCID: https://orcid.org/0009-0002-5618-4833)
- Beiyu Wang (ORCID: https://orcid.org/0000-0001-8755-1427)
- Kangkang Huang
- Yi Deng
- Tingkui Wu
Institutions
- Sichuan University (CN)
- West China Hospital of Sichuan University (CN)
Publication Details
- Journal
- Orthopaedic Surgery
- Published
- 2026-11-22
- DOI
- https://doi.org/10.1111/os.70474
- Primary Topic
- Cervical and Thoracic Myelopathy
- Type
- article
- Field-Weighted Citation Impact
- 0.00