Does a draining liquid film remember its history? Surface cooling by drainage as a thermal memory, from molecular dynamics and a validated fluctuating free-film model

Coalescence kernels for bubbly flows assume that the film between two bubbles ruptures at a rate set by its present state. We tested this with molecular dynamics of Lennard–Jones films drained by a body force. Films brought to the same central thickness while thinning under the same force, either directly or after being drained further and refilled, were driven identically. Without local heat exchange, the refilled films reached a drainage end point earlier (hazard ratio 2.3, 100 trajectories per group, confirmed by pre-specified replication) and formed the first hole earlier. A fluctuating free-film model validated against molecular dynamics predicted none. The difference lay in a temperature field created by the drainage. A stretched surface absorbs heat −T dγ/dT per unit area created, so the thinning centre cooled. Refilling compressed its surfaces and warmed it. A heat balance driven by the measured flow, without fitted parameters, accounted for 0.6–1.4 of the cooling and for most of the warming by the refill. Films without thermostat behaved as under a global Nosé–Hoover thermostat. The colder centre opposes drainage by thermocapillary stress, and the model with the measured temperature profiles predicted the drainage-rate difference (15 ± 2% against 19 ± 4%). Local, momentum-conserving heat removal eliminated the temperature difference and the history effect (hazard ratio 1.00, 0.76–1.32). For aqueous films, heat supply from the gas limits the cooling to hundredths to tenths of a kelvin, which in fast drainage of mobile films can still give thermocapillary stresses comparable to the capillary drive.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-22
DOI
https://doi.org/10.5281/zenodo.24440494
Primary Topic
Fluid Dynamics and Thin Films
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Does a draining liquid film remember its history? Surface cooling by drainage as a thermal memory, from molecular dynamics and a validated fluctuating free-film model

舟 鲍, Duan Zhuoqi, Hu Yongmao, Xie Zaixin
Zenodo (CERN European Organization for Nuclear Research)
Fluid Dynamics and Thin Films
preprint

Does a draining liquid film remember its history? Surface cooling by drainage as a thermal memory, from molecular dynamics and a validated fluctuating free-film model

舟 鲍, Duan Zhuoqi, Hu Yongmao, Xie Zaixin
preprint en

Abstract

Coalescence kernels for bubbly flows assume that the film between two bubbles ruptures at a rate set by its present state. We tested this with molecular dynamics of Lennard–Jones films drained by a body force. Films brought to the same central thickness while thinning under the same force, either directly or after being drained further and refilled, were driven identically. Without local heat exchange, the refilled films reached a drainage end point earlier (hazard ratio 2.3, 100 trajectories per group, confirmed by pre-specified replication) and formed the first hole earlier. A fluctuating free-film model validated against molecular dynamics predicted none. The difference lay in a temperature field created by the drainage. A stretched surface absorbs heat −T dγ/dT per unit area created, so the thinning centre cooled. Refilling compressed its surfaces and warmed it. A heat balance driven by the measured flow, without fitted parameters, accounted for 0.6–1.4 of the cooling and for most of the warming by the refill. Films without thermostat behaved as under a global Nosé–Hoover thermostat. The colder centre opposes drainage by thermocapillary stress, and the model with the measured temperature profiles predicted the drainage-rate difference (15 ± 2% against 19 ± 4%). Local, momentum-conserving heat removal eliminated the temperature difference and the history effect (hazard ratio 1.00, 0.76–1.32). For aqueous films, heat supply from the gas limits the cooling to hundredths to tenths of a kelvin, which in fast drainage of mobile films can still give thermocapillary stresses comparable to the capillary drive.

Zenodo (CERN European Organization for Nuclear Research)
Dali University (CN)
Fluid Dynamics and Thin Films
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Does a draining liquid film remember its history? Surface cooling by drainage as a thermal memory, from molecular dynamics and a validated fluctuating free-film model — 舟 鲍, Duan Zhuoqi, et al. · Zenodo (CERN European Organization for Nuclear Research) (2026) | TGRS Research Map | TGRS