Preoperative Hemoglobin-Guided Blood Monitoring Protocol for Total Knee Arthroplasty: Reducing Unnecessary Laboratory Testing While Maintaining Patient Safety

Background Routine postoperative hemoglobin (Hb) monitoring after total knee arthroplasty (TKA) is commonly performed on days 1 and 2 for all patients regardless of transfusion risk, potentially resulting in unnecessary laboratory testing. We describe and evaluate a preoperative Hb-guided monitoring protocol to reduce blood sampling while maintaining patient safety. Methods This prospective cohort study enrolled 335 patients undergoing primary TKA (131 bilateral, 204 unilateral). All patients received tranexamic acid and tourniquet. Hb was measured preoperatively and on postoperative days 1 and 2. Transfusion was indicated for Hb <8.0 g/dL or symptomatic anemia. Only Hb-based transfusions were used to determine optimal preoperative cut-off values using Youden Index analysis. Results Sixty-three patients (18.8%) received transfusions; 35 (55.6%) were Hb-based. A preoperative cutoff of 13.0 g/dL provided optimal discrimination (sensitivity 93.8%, specificity 53.1%). In bilateral TKA, Hb-based transfusion rates were 3.7% (Hb > 13 g/dL) vs 39.0% (Hb ≤ 13 g/dL) ( P < .001). In unilateral TKA, the rate was 1.0% (1/100) in patients with Hb ≥ 13 g/dL. The proposed protocol would reduce blood sampling by 37.9% while maintaining 98.4% sensitivity for detecting transfusion requirements. Conclusions This protocol substantially reduced routine blood sampling by 37.9% while maintaining high sensitivity for transfusion detection. Selectively eliminating routine monitoring in low-risk patients—specifically unilateral TKA patients with preoperative Hb ≥13.0 g/dL—preserves resources with an excellent safety profile, supporting consideration as an institutional protocol. Multicenter validation is recommended to establish broader generalizability. Level of Evidence Level II, prospective cohort study.

Authors

Institutions

Publication Details

Journal
Arthroplasty Today
Published
2026-11-22
DOI
https://doi.org/10.1016/j.artd.2026.102219
Primary Topic
Blood transfusion and management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Preoperative Hemoglobin-Guided Blood Monitoring Protocol for Total Knee Arthroplasty: Reducing Unnecessary Laboratory Testing While Maintaining Patient Safety

Rapeepat Narkbunnam, Chaiwat Achawakulthep, Payap Payapapnon, Keerati Chareancholvanich et al.
Arthroplasty Today
Blood transfusion and management
article

Preoperative Hemoglobin-Guided Blood Monitoring Protocol for Total Knee Arthroplasty: Reducing Unnecessary Laboratory Testing While Maintaining Patient Safety

Rapeepat Narkbunnam, Chaiwat Achawakulthep, Payap Payapapnon, Keerati Chareancholvanich, Chaturong Pornrattanamaneewong, Kit Awirotananon
article en

Abstract

Background Routine postoperative hemoglobin (Hb) monitoring after total knee arthroplasty (TKA) is commonly performed on days 1 and 2 for all patients regardless of transfusion risk, potentially resulting in unnecessary laboratory testing. We describe and evaluate a preoperative Hb-guided monitoring protocol to reduce blood sampling while maintaining patient safety. Methods This prospective cohort study enrolled 335 patients undergoing primary TKA (131 bilateral, 204 unilateral). All patients received tranexamic acid and tourniquet. Hb was measured preoperatively and on postoperative days 1 and 2. Transfusion was indicated for Hb <8.0 g/dL or symptomatic anemia. Only Hb-based transfusions were used to determine optimal preoperative cut-off values using Youden Index analysis. Results Sixty-three patients (18.8%) received transfusions; 35 (55.6%) were Hb-based. A preoperative cutoff of 13.0 g/dL provided optimal discrimination (sensitivity 93.8%, specificity 53.1%). In bilateral TKA, Hb-based transfusion rates were 3.7% (Hb > 13 g/dL) vs 39.0% (Hb ≤ 13 g/dL) ( P < .001). In unilateral TKA, the rate was 1.0% (1/100) in patients with Hb ≥ 13 g/dL. The proposed protocol would reduce blood sampling by 37.9% while maintaining 98.4% sensitivity for detecting transfusion requirements. Conclusions This protocol substantially reduced routine blood sampling by 37.9% while maintaining high sensitivity for transfusion detection. Selectively eliminating routine monitoring in low-risk patients—specifically unilateral TKA patients with preoperative Hb ≥13.0 g/dL—preserves resources with an excellent safety profile, supporting consideration as an institutional protocol. Multicenter validation is recommended to establish broader generalizability. Level of Evidence Level II, prospective cohort study.

Arthroplasty TodayVol. 42
Siriraj Hospital (TH), Mahidol University (TH)
Blood transfusion and management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon