Use of the oxygen tolerance unit to measure potential pulmonary oxygen toxicity in critically ill patients? A secondary analysis of the ICU-ROX randomised trial

PaO₂ and SpO₂ measure oxygen in the blood, not the dose reaching the lung. Diop and colleagues proposed the oxygen tolerance unit (OTU), a diving-medicine measure of cumulative pulmonary oxygen dose, untested in critical illness. OTU = t × ((PIO₂ − 0.5)/0.5)^0.83, where t is minutes and PIO₂ is inspired oxygen pressure in atmospheres; nothing accrues at or below 0.5 atm, an FiO₂ of 0.50 at sea level. We calculated cumulative OTU from six-hourly FiO₂ over study days 0 to 10 in 965 ICU-ROX patients, and asked whether the formula fits when cut-off and exponent are profiled jointly, whether the exposure is common, and whether dose is associated with death. Median cumulative OTU was 0 (IQR 0–95); 67% accrued no dose from the sampled readings, dose being concentrated in severe hypoxaemia. Fewer in the conservative group crossed the threshold (71% versus 63% accrued none, P = 0.01); among those who did, dose did not differ detectably, though that comparison conditions on a post-randomisation variable. The best-fitting FiO₂ cut-off against mortality was 0.21, the published values falling outside the supported range. OTU was associated with 90-day mortality (adjusted OR 1.13, 1.06–1.21 per 100) but fitted no better than mean PEEP. In unselected ventilated patients, OTU fitted 90-day mortality less well than simpler measures of oxygen exposure. Its cut-off at FiO₂ 0.50 is the feature these data support least, though model fit cannot separate severity from toxicity. Calculated exposure was zero in most patients under this formula, but not in severe hypoxaemia. ICU-ROX was registered with the Australian New Zealand Clinical Trials Registry, registration number ACTRN12615000957594. The present study is a secondary analysis of that trial and was not separately registered. ICU-ROX, Australian New Zealand Clinical Trials Registry ACTRN12615000957594.

Authors

Institutions

Publication Details

Journal
Critical Care
Published
2026-11-23
DOI
https://doi.org/10.1186/s13054-026-06450-7
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Use of the oxygen tolerance unit to measure potential pulmonary oxygen toxicity in critically ill patients? A secondary analysis of the ICU-ROX randomised trial

Hannah Smellie, Jasmin Board, Aidan J. C. Burrell, Aimee Blakemore et al.
1 links
Critical Care
Respiratory Support and Mechanisms
article

Use of the oxygen tolerance unit to measure potential pulmonary oxygen toxicity in critically ill patients? A secondary analysis of the ICU-ROX randomised trial

Hannah Smellie, Jasmin Board, Aidan J. C. Burrell, Aimee Blakemore, Andrew Greer, Keri-Anne Cowdrey, Alex Kazemi, Catherine Simmonds, Chris Mason, Michael Bailey, Eliza Dean, Jefferson Aguila, Rinaldo Bellomo, Rica Dagooc, Carolyn Jackson, Debra Chalmers, Phoebe McCracken, Ross Freebairn, Emma Martin, David Knight, Alex J. Psirides, Jay Ritzema Carter, Shirley Vallance, Jonathan Albrett, Jessica Roberts, Sheila Caniba, Danielle Hacking, Shawn Sturland, Rosalind Crombie, Eden Lesona, David Closey, Ulrike Buehner, Paul Jeffrey Young, Neil Davidson, Seton J. Henderson, Christine Rolls, Emmeline Minto, Kim Parker, Anisha Dias, Rachael C. McConnochie, Glenn M. Eastwood, Magdalena Butler, Brandon Burke, Jane Hallion, Harriet Judd, Colin J. McArthur, Rachael L. Parke, Yvonne Robertson, Frances Fitzjohn, Sacha Richardson, Carmel Chapman, Leanlove Navarra, Peter R. Hicks, Ubbo F. Wiersema, Shailesh Bihari, Louise Hitchings, Penelope Park, Shay McGuinness, Rima Song, Ben Barry, Stephanie Long, Stacey Morgan, Maud Carpenter, David Bowie, Philippa Neal, Anna Hunt, Samantha J. Edney, Eileen Gilder, Dick Dinsdale, Samantha Wallace, Cassie Lawrence, Katherine Townend, Diane Mackle, Christian Sahl, Ywain Thomas Lawrey, Leah Peck, Meredith Young, Geoffrey M. Shaw, Georgia Hill, Anna Morris, Tony Williams, Lynette Newby, Jan E. Mehrtens, Raulle Sol Cruz, Bob Ure, Llesley Chadwick, Niña Beehre, Andrew Stapleton, Paul Young, Erin Williams, Vivian Lai, Tim Byrne, Peter Marko, Agnes McKay Vucago, Chris Poynter, Michael Park, Charlotte Latimer Bell, Yan Chen, Kate Miller, the ICU-ROX Investigators
article en

Abstract

PaO₂ and SpO₂ measure oxygen in the blood, not the dose reaching the lung. Diop and colleagues proposed the oxygen tolerance unit (OTU), a diving-medicine measure of cumulative pulmonary oxygen dose, untested in critical illness. OTU = t × ((PIO₂ − 0.5)/0.5)^0.83, where t is minutes and PIO₂ is inspired oxygen pressure in atmospheres; nothing accrues at or below 0.5 atm, an FiO₂ of 0.50 at sea level. We calculated cumulative OTU from six-hourly FiO₂ over study days 0 to 10 in 965 ICU-ROX patients, and asked whether the formula fits when cut-off and exponent are profiled jointly, whether the exposure is common, and whether dose is associated with death. Median cumulative OTU was 0 (IQR 0–95); 67% accrued no dose from the sampled readings, dose being concentrated in severe hypoxaemia. Fewer in the conservative group crossed the threshold (71% versus 63% accrued none, P = 0.01); among those who did, dose did not differ detectably, though that comparison conditions on a post-randomisation variable. The best-fitting FiO₂ cut-off against mortality was 0.21, the published values falling outside the supported range. OTU was associated with 90-day mortality (adjusted OR 1.13, 1.06–1.21 per 100) but fitted no better than mean PEEP. In unselected ventilated patients, OTU fitted 90-day mortality less well than simpler measures of oxygen exposure. Its cut-off at FiO₂ 0.50 is the feature these data support least, though model fit cannot separate severity from toxicity. Calculated exposure was zero in most patients under this formula, but not in severe hypoxaemia. ICU-ROX was registered with the Australian New Zealand Clinical Trials Registry, registration number ACTRN12615000957594. The present study is a secondary analysis of that trial and was not separately registered. ICU-ROX, Australian New Zealand Clinical Trials Registry ACTRN12615000957594.

Critical Care
Flinders University (AU), Wellington Hospital (NZ), Flinders Medical Centre (AU), Medical Research Institute of New Zealand (NZ), Monash University (AU)
Royal Adelaide Hospital, Fiona Stanley Hospital, Health Research Council of New Zealand
Good health and well-being
Respiratory Support and Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon