1304-GRP CG-ECG: A Selective Classification Abstention Framework for Trustworthy ECG Classification

Reliable electrocardiogram (ECG) classification requires more than assigning every rhythm segment to the most likely class. In computer- aided diagnosis, a model should also know when a prediction is not sufficiently reliable for automatic retention and should instead be de- ferred to human-in-the-loop review. This paper presents CG-ECG, a two- gate confidence-geometry abstention framework for trustworthy ECG- based computer-aided diagnosis. The first gate evaluates output-level confidence using maximum softmax probability or predictive entropy. The second gate evaluates representation-level support by projecting penultimate-layer embeddings with singular value decomposition and constructing class-specific convex-hull regions from true-positive train- ing embeddings. A prediction is retained only when it passes a confi- dence gate and is geometrically supported by the predicted class region. The framework is evaluated on two public ECG benchmarks: a MIT- BIH arrhythmia classification setting using 1D ECG signals and 2D waveform-image representations and a PTB-XL 1D time-series bench- mark using a stratified held-out test split. Results show that confidence gates are strong selective baselines, achieving zero retained errors at approximately 60 to 64% coverage on MIT-BIH. Geometry alone does not uniformly outperform confidence thresholding, but it provides com- plementary representation-level evidence and auditable deferral causes. On PTB-XL, the geometry-only gate at k = 2 reduces retained er- rors by 50% relative to forced classification while preserving high cover- age. These findings position confidence-geometry abstention as an inter- pretable selective-classification framework for ECG-based CAD

Authors

Publication Details

Journal
DigitalCommons - Kennesaw State University (Kennesaw State University)
Published
2026-11-20
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

1304-GRP CG-ECG: A Selective Classification Abstention Framework for Trustworthy ECG Classification

Masroor Ul Hasan Syed
DigitalCommons - Kennesaw State University (Kennesaw State University)
ECG Monitoring and Analysis
article

1304-GRP CG-ECG: A Selective Classification Abstention Framework for Trustworthy ECG Classification

Masroor Ul Hasan Syed
article en

Abstract

Reliable electrocardiogram (ECG) classification requires more than assigning every rhythm segment to the most likely class. In computer- aided diagnosis, a model should also know when a prediction is not sufficiently reliable for automatic retention and should instead be de- ferred to human-in-the-loop review. This paper presents CG-ECG, a two- gate confidence-geometry abstention framework for trustworthy ECG- based computer-aided diagnosis. The first gate evaluates output-level confidence using maximum softmax probability or predictive entropy. The second gate evaluates representation-level support by projecting penultimate-layer embeddings with singular value decomposition and constructing class-specific convex-hull regions from true-positive train- ing embeddings. A prediction is retained only when it passes a confi- dence gate and is geometrically supported by the predicted class region. The framework is evaluated on two public ECG benchmarks: a MIT- BIH arrhythmia classification setting using 1D ECG signals and 2D waveform-image representations and a PTB-XL 1D time-series bench- mark using a stratified held-out test split. Results show that confidence gates are strong selective baselines, achieving zero retained errors at approximately 60 to 64% coverage on MIT-BIH. Geometry alone does not uniformly outperform confidence thresholding, but it provides com- plementary representation-level evidence and auditable deferral causes. On PTB-XL, the geometry-only gate at k = 2 reduces retained er- rors by 50% relative to forced classification while preserving high cover- age. These findings position confidence-geometry abstention as an inter- pretable selective-classification framework for ECG-based CAD

DigitalCommons - Kennesaw State University (Kennesaw State University)
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
1304-GRP CG-ECG: A Selective Classification Abstention Framework for Trustworthy ECG Classification — Masroor Ul Hasan Syed · DigitalCommons - Kennesaw State University (Kennesaw State University) (2026) | TGRS Research Map | TGRS