1250-GRM Multi-Organ Tumor Classification and Zero-Shot Cross-Organ Transfer

In this study, two methods of medical image analysis were performed using ResNet-50. Experiment 1 trains a shared convolutional backbone with separate four-class heads for brain MRI, kidney CT, and lung CT classification. Experiment 2 tests zero-shot cross-organ transfer: a binary (yes or no) lesion classifier trained only on brain and kidney images then tested on unseen lung CT scans. Zero-shot refers to the model performing a prediction on unseen data without training or fine-tuning. The supervised multi-organ experiment displayed accuracies of 92.95% for the brain, 99.96% for the kidney, and 90.28% for the lung. In contrast, the zero-shot evaluation only displayed an accuracy of 30%. These findings illustrate the challenge of generalizing across organs and imaging domains.

Authors

Publication Details

Journal
DigitalCommons - Kennesaw State University (Kennesaw State University)
Published
2026-11-20
Primary Topic
Domain Adaptation and Few-Shot Learning
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

1250-GRM Multi-Organ Tumor Classification and Zero-Shot Cross-Organ Transfer

Theodore King
DigitalCommons - Kennesaw State University (Kennesaw State University)
Domain Adaptation and Few-Shot Learning
article

1250-GRM Multi-Organ Tumor Classification and Zero-Shot Cross-Organ Transfer

Theodore King
article en

Abstract

In this study, two methods of medical image analysis were performed using ResNet-50. Experiment 1 trains a shared convolutional backbone with separate four-class heads for brain MRI, kidney CT, and lung CT classification. Experiment 2 tests zero-shot cross-organ transfer: a binary (yes or no) lesion classifier trained only on brain and kidney images then tested on unseen lung CT scans. Zero-shot refers to the model performing a prediction on unseen data without training or fine-tuning. The supervised multi-organ experiment displayed accuracies of 92.95% for the brain, 99.96% for the kidney, and 90.28% for the lung. In contrast, the zero-shot evaluation only displayed an accuracy of 30%. These findings illustrate the challenge of generalizing across organs and imaging domains.

DigitalCommons - Kennesaw State University (Kennesaw State University)
Domain Adaptation and Few-Shot Learning
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon