Occupancy-Gated Fuzzy Logic Control for Energy-Efficient Air-Conditioning in Context-Aware Smart Homes: A Simulation Study

Air-conditioning is the largest single electrical load in many homes, and the on/off thermostats that still govern most units run at full power, cycle the compressor often, and keep cooling empty rooms. This study designs and evaluates a context-aware fuzzy logic controller that reads two signals, room temperature and occupancy, and sets air-conditioner power. A single room was modelled as a first-order thermal plant and controlled by Mamdani fuzzy inference system. An initial design, V1, treated occupancy as a soft influence and overcooled empty rooms. A corrected design, V2, writes occupancy into the rule base as a gate with an explicit off state, so an empty room drives cooling to zero. The controllers were re-implemented in Python and compared against an on/off thermostat and an occupancy-aware thermostat under a fixed 180-minute test, a 24 h day, and 300 randomised scenarios, with switching counted for every controller by one threshold-crossing metric. With the room occupied throughout the fixed test, V2 stayed in the comfort band 99.2 % of the time on 1.05 kWh against 1.13 kWh for the thermostat, without switching. On realistic days V2 cut mean daily energy by 18.5 %, but occupied comfort fell to 88.7 % on average against 97.1 % for the thermostat, a trade-off of about eight points, and V2 still restarted the compressor about five times a day against 129 for the thermostat. Most of the saving came from not cooling an empty room. An occupancy-aware thermostat captured most of it without any fuzzy inference.

Authors

Institutions

Publication Details

Journal
Lafia Journal of Scientific and industrial Research
Published
2026-11-21
DOI
https://doi.org/10.62050/ljsir2027.v5n1.959
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Occupancy-Gated Fuzzy Logic Control for Energy-Efficient Air-Conditioning in Context-Aware Smart Homes: A Simulation Study

Ikenna Augustine Onyegbadue, Fred Abeibhode Izilein, Chima Kesniel Igumbor
Lafia Journal of Scientific and industrial Research
Building Energy and Comfort Optimization
article

Occupancy-Gated Fuzzy Logic Control for Energy-Efficient Air-Conditioning in Context-Aware Smart Homes: A Simulation Study

Ikenna Augustine Onyegbadue, Fred Abeibhode Izilein, Chima Kesniel Igumbor
article en

Abstract

Air-conditioning is the largest single electrical load in many homes, and the on/off thermostats that still govern most units run at full power, cycle the compressor often, and keep cooling empty rooms. This study designs and evaluates a context-aware fuzzy logic controller that reads two signals, room temperature and occupancy, and sets air-conditioner power. A single room was modelled as a first-order thermal plant and controlled by Mamdani fuzzy inference system. An initial design, V1, treated occupancy as a soft influence and overcooled empty rooms. A corrected design, V2, writes occupancy into the rule base as a gate with an explicit off state, so an empty room drives cooling to zero. The controllers were re-implemented in Python and compared against an on/off thermostat and an occupancy-aware thermostat under a fixed 180-minute test, a 24 h day, and 300 randomised scenarios, with switching counted for every controller by one threshold-crossing metric. With the room occupied throughout the fixed test, V2 stayed in the comfort band 99.2 % of the time on 1.05 kWh against 1.13 kWh for the thermostat, without switching. On realistic days V2 cut mean daily energy by 18.5 %, but occupied comfort fell to 88.7 % on average against 97.1 % for the thermostat, a trade-off of about eight points, and V2 still restarted the compressor about five times a day against 129 for the thermostat. Most of the saving came from not cooling an empty room. An occupancy-aware thermostat captured most of it without any fuzzy inference.

Lafia Journal of Scientific and industrial Research
Igbinedion University (NG)
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Occupancy-Gated Fuzzy Logic Control for Energy-Efficient Air-Conditioning in Context-Aware Smart Homes: A Simulation Study — Ikenna Augustine Onyegbadue, Fred Abeibhode Izilein, et al. · Lafia Journal of Scientific and industrial Research (2026) | TGRS Research Map | TGRS