AQUIFER PARAMETER VARIATION USING VERTICAL ELECTRICAL SOUNDING AND CONTOURING TECHNIQUES IN APETE-AKUFO PHASE II, AWOTAN-ASUNLE AREA OF IBADAN, SOUTH-WEST NIGERIA

Subsurface characterization is essential for evaluating groundwater potential and assess the environmental impact of dumpsites. Vertical Electrical Sounding (VES) was carried out to study the subsurface condition of Apete-Akufo, Awotan-Asunle dumpsite area of Ibadan, aimed at determining the subsurface resistivity beneath the dumpsite, identifying the different geoelectric layers present, evaluating the depth and extent of leachate contamination. Ten (10) Vertical Electrical Sounding (VES) stations were occupied using Schlumberger electrode configuration with half-electrode spacing (AB/2) of 75m each and the field data were interpreted using Win Resist software to generate geoelectric models. The interpreted results revealed three to four geoelectric layers comprising the topsoil, weathered layer, fractured basement, and fresh basement. The top soil resistivity values range from 8.1Ωm to 800.2Ωm, the weathered layer resistivity (4.1-619.1Ωm), fractured basement resistivity ranges from 25.6Ωm to 105.6Ωm and fresh basement resistivity (25.7-1291.6Ωm) with curves types ranging from H-type to A-type and K-type across the different stations. Other aquifer properties were consequently determined; bedrock relief which ranges from 187.5 to 221.3m, Aquifer thickness (0.5 - 41.7m) and overburden thickness ranges from 2.7 to 44.5m among others. The aquifer protective capacity assessment, based on longitudinal conductance values, revealed that 10%, 20%, 60% and 10% were classified as poor, weak, moderate and good protective capacity status respectively. The location exhibiting low protective capacity will enhance the migration of contaminants into the groundwater system of the study area. Periodic groundwater quality monitoring is recommended particularly in locations with low aquifer protective capacity to minimize the impact of leachate contamination from the dumpsite.

Authors

Institutions

Publication Details

Journal
Journal of African Advancement and Sustainability Studies
Published
2026-11-21
DOI
https://doi.org/10.70382/sjaass.v14i2.0104
Primary Topic
Geophysical and Geoelectrical Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

AQUIFER PARAMETER VARIATION USING VERTICAL ELECTRICAL SOUNDING AND CONTOURING TECHNIQUES IN APETE-AKUFO PHASE II, AWOTAN-ASUNLE AREA OF IBADAN, SOUTH-WEST NIGERIA

S. A. ISHOLA
Journal of African Advancement and Sustainability Studies
Geophysical and Geoelectrical Methods
article

AQUIFER PARAMETER VARIATION USING VERTICAL ELECTRICAL SOUNDING AND CONTOURING TECHNIQUES IN APETE-AKUFO PHASE II, AWOTAN-ASUNLE AREA OF IBADAN, SOUTH-WEST NIGERIA

S. A. ISHOLA
article en

Abstract

Subsurface characterization is essential for evaluating groundwater potential and assess the environmental impact of dumpsites. Vertical Electrical Sounding (VES) was carried out to study the subsurface condition of Apete-Akufo, Awotan-Asunle dumpsite area of Ibadan, aimed at determining the subsurface resistivity beneath the dumpsite, identifying the different geoelectric layers present, evaluating the depth and extent of leachate contamination. Ten (10) Vertical Electrical Sounding (VES) stations were occupied using Schlumberger electrode configuration with half-electrode spacing (AB/2) of 75m each and the field data were interpreted using Win Resist software to generate geoelectric models. The interpreted results revealed three to four geoelectric layers comprising the topsoil, weathered layer, fractured basement, and fresh basement. The top soil resistivity values range from 8.1Ωm to 800.2Ωm, the weathered layer resistivity (4.1-619.1Ωm), fractured basement resistivity ranges from 25.6Ωm to 105.6Ωm and fresh basement resistivity (25.7-1291.6Ωm) with curves types ranging from H-type to A-type and K-type across the different stations. Other aquifer properties were consequently determined; bedrock relief which ranges from 187.5 to 221.3m, Aquifer thickness (0.5 - 41.7m) and overburden thickness ranges from 2.7 to 44.5m among others. The aquifer protective capacity assessment, based on longitudinal conductance values, revealed that 10%, 20%, 60% and 10% were classified as poor, weak, moderate and good protective capacity status respectively. The location exhibiting low protective capacity will enhance the migration of contaminants into the groundwater system of the study area. Periodic groundwater quality monitoring is recommended particularly in locations with low aquifer protective capacity to minimize the impact of leachate contamination from the dumpsite.

Journal of African Advancement and Sustainability Studies
Olabisi Onabanjo University (NG)
Geophysical and Geoelectrical Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon