Reprocessing a fiducial-assisted cryo-EM dataset clarifies the structural details of human Frizzled5

Single-particle cryogenic electron microscopy of transducer-free G protein-coupled receptors (GPCRs) relies on fiducial markers to bypass size limits and mitigate micelle-induced low signal-to-noise ratios. However, continuous inter-domain flexibility between the receptor and the marker can limit local resolution. Using modern cryoSPARC algorithms, I reprocessed a previously published dataset of unliganded human Frizzled5 (hFzd5) complexed with a tripartite fiducial system to overcome previous resolution limits. While recent software advancements primarily drove a substantial enhancement in overall resolution, doming-induced specimen tilting and potential domain flexing during electron exposure can still introduce residual blur under a global mask. To resolve this, I restricted trajectory estimation exclusively to the receptor core via focused reference-based motion correction (fRBMC), which provided a further modest improvement in map quality. Subsequent quantitative trajectory analysis showed that the trajectory estimated using a local receptor mask differed from that of the global mask, reaching an average of approximately 2 Å by frame 20. Concluding the workflow with local refinement yielded a final map at 3.27 Å nominal resolution, enabling a more accurate structural re-analysis and interpretation of the extracellular disulfide network.

Authors

Publication Details

Journal
Microscopy
Published
2026-11-20
DOI
https://doi.org/10.1093/jmicro/dfag044
Primary Topic
Advanced Electron Microscopy Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Reprocessing a fiducial-assisted cryo-EM dataset clarifies the structural details of human Frizzled5

Naotaka Tsutsumi
Microscopy
Advanced Electron Microscopy Techniques and Applications
article

Reprocessing a fiducial-assisted cryo-EM dataset clarifies the structural details of human Frizzled5

Naotaka Tsutsumi
article en

Abstract

Single-particle cryogenic electron microscopy of transducer-free G protein-coupled receptors (GPCRs) relies on fiducial markers to bypass size limits and mitigate micelle-induced low signal-to-noise ratios. However, continuous inter-domain flexibility between the receptor and the marker can limit local resolution. Using modern cryoSPARC algorithms, I reprocessed a previously published dataset of unliganded human Frizzled5 (hFzd5) complexed with a tripartite fiducial system to overcome previous resolution limits. While recent software advancements primarily drove a substantial enhancement in overall resolution, doming-induced specimen tilting and potential domain flexing during electron exposure can still introduce residual blur under a global mask. To resolve this, I restricted trajectory estimation exclusively to the receptor core via focused reference-based motion correction (fRBMC), which provided a further modest improvement in map quality. Subsequent quantitative trajectory analysis showed that the trajectory estimated using a local receptor mask differed from that of the global mask, reaching an average of approximately 2 Å by frame 20. Concluding the workflow with local refinement yielded a final map at 3.27 Å nominal resolution, enabling a more accurate structural re-analysis and interpretation of the extracellular disulfide network.

Microscopy
Advanced Electron Microscopy Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.