Experimental limitations introduced during cluster analysis in super-resolution microscopy due to the choice of labeling methods and fluorophores

Advances in super-resolution fluorescence microscopy, particularly single-molecule localization microscopy (SMLM) techniques such as Photoactivated Localization Microscopy (PALM) and direct Stochastic Optical Reconstruction Microscopy (dSTORM), have enabled the precise visualization and quantification of individual protein molecules and the higher-order complexes formed. However, the relative accuracy and limitations of labeling and imaging parameters in quantifying diffraction-limited protein nanoclusters remain poorly characterized. Using well-characterized 2D focal adhesion kinase (FAK) clusters as a benchmark, we combined Monte Carlo simulations and experiments to assess labeling-induced errors. Antibody-based dSTORM exhibited up to ~42% quantification error relative to PALM, which decreased with smaller probes or monovalent nanobodies. In addition, we highlight other considerations for SMLM, including the clonality of the antibody, the number of fluorophores per antibody, steric hindrance to antibody binding, stochastic blinking of the fluorophore, and how to measure their effects to obtain a more accurate measure of the protein clusters or complexes. By systematically quantifying the contribution of linkage error to nanocluster size quantification, our study establishes a baseline for comparing its impact across the SMLM methods, which is critical for translating molecular localization into mechanistic biological insight.

Authors

Institutions

Publication Details

Journal
npj Biological Physics and Mechanics.
Published
2026-11-21
DOI
https://doi.org/10.1038/s44341-026-00057-3
Primary Topic
Advanced Fluorescence Microscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Experimental limitations introduced during cluster analysis in super-resolution microscopy due to the choice of labeling methods and fluorophores

Kashish Jain, Valerie Marie Weaver, Rishita Changede, Pakorn Kanchanawong
npj Biological Physics and Mechanics.
Advanced Fluorescence Microscopy Techniques
article

Experimental limitations introduced during cluster analysis in super-resolution microscopy due to the choice of labeling methods and fluorophores

Kashish Jain, Valerie Marie Weaver, Rishita Changede, Pakorn Kanchanawong
article en

Abstract

Advances in super-resolution fluorescence microscopy, particularly single-molecule localization microscopy (SMLM) techniques such as Photoactivated Localization Microscopy (PALM) and direct Stochastic Optical Reconstruction Microscopy (dSTORM), have enabled the precise visualization and quantification of individual protein molecules and the higher-order complexes formed. However, the relative accuracy and limitations of labeling and imaging parameters in quantifying diffraction-limited protein nanoclusters remain poorly characterized. Using well-characterized 2D focal adhesion kinase (FAK) clusters as a benchmark, we combined Monte Carlo simulations and experiments to assess labeling-induced errors. Antibody-based dSTORM exhibited up to ~42% quantification error relative to PALM, which decreased with smaller probes or monovalent nanobodies. In addition, we highlight other considerations for SMLM, including the clonality of the antibody, the number of fluorophores per antibody, steric hindrance to antibody binding, stochastic blinking of the fluorophore, and how to measure their effects to obtain a more accurate measure of the protein clusters or complexes. By systematically quantifying the contribution of linkage error to nanocluster size quantification, our study establishes a baseline for comparing its impact across the SMLM methods, which is critical for translating molecular localization into mechanistic biological insight.

npj Biological Physics and Mechanics.Vol. 3(1)
National University of Singapore (SG), University of California, San Francisco (US), UCSF Helen Diller Family Comprehensive Cancer Center (US), Mechanobiology Institute (SG)
Advanced Fluorescence Microscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Experimental limitations introduced during cluster analysis in super-resolution microscopy due to the choice of labeling methods and fluorophores — Kashish Jain, Valerie Marie Weaver, et al. · npj Biological Physics and Mechanics. (2026) | TGRS Research Map | TGRS