Evaluating the effects of changes in minute ventilation and the partial pressure of end‐tidal carbon dioxide on the diaphragm electromyogram during voluntary hyperpnoea

The diaphragm electromyogram (EMG DIA ) is commonly used as a proxy for inspiratory neural drive (IND) based on correlative evidence; however, robust experimental evidence supporting its use is lacking. To determine the effects of independent changes in minute ventilation () and the partial pressure of end‐tidal carbon dioxide () on EMG DIA . n = 10 healthy adults (20–40 years; n = 5 males, n = 5 females) completed spirometry, a 10‐min rest period and a series of hyperpnoea trials at three standardized levels of by having participants breathe according to tidal volume ( V T ) and breathing frequency ( F B ) targets. Within each level of , was set to −5, +0 or +5 mmHg relative to resting using dynamic end‐tidal forcing. Trials were performed in a quasi‐randomized, single‐blind manner. EMG DIA was assessed using an intraoesophageal catheter, standard ventilatory and gas exchange variables were collected, and the perception of dyspnoea intensity was assessed using the Borg category‐ratio 0–10 scale. EMG DIA increased significantly with ( P < 0.001) but was unaffected by changes in ( P = 0.320). Moreover, EMG DIA was significantly associated with , the work of breathing, and the pressure–time product of the diaphragm ( R 2 = 0.762–0.824; all P < 0.001), but not ( R 2 = 0.529; P = 0.947). Dyspnoea perception increased significantly with ( P < 0.001) and ( P < 0.001). During voluntary hyperpnoea involving manipulations of across a physiological range observed with exercise (i.e., 5 mmHg below and above resting ), EMG DIA reflects the mechanical ventilatory output of IND rather than changes in the drive to breathe due to variations in .

Authors

Institutions

Publication Details

Journal
Experimental Physiology
Published
2026-11-21
DOI
https://doi.org/10.1113/ep094174
Primary Topic
Neuroscience of respiration and sleep
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Evaluating the effects of changes in minute ventilation and the partial pressure of end‐tidal carbon dioxide on the diaphragm electromyogram during voluntary hyperpnoea

Yannick Molgat‐Seon, Leah M. Mann, Paolo B. Dominelli, Jack R. Dunsford
Experimental Physiology
Neuroscience of respiration and sleep
article

Evaluating the effects of changes in minute ventilation and the partial pressure of end‐tidal carbon dioxide on the diaphragm electromyogram during voluntary hyperpnoea

Yannick Molgat‐Seon, Leah M. Mann, Paolo B. Dominelli, Jack R. Dunsford
article en

Abstract

The diaphragm electromyogram (EMG DIA ) is commonly used as a proxy for inspiratory neural drive (IND) based on correlative evidence; however, robust experimental evidence supporting its use is lacking. To determine the effects of independent changes in minute ventilation () and the partial pressure of end‐tidal carbon dioxide () on EMG DIA . n = 10 healthy adults (20–40 years; n = 5 males, n = 5 females) completed spirometry, a 10‐min rest period and a series of hyperpnoea trials at three standardized levels of by having participants breathe according to tidal volume ( V T ) and breathing frequency ( F B ) targets. Within each level of , was set to −5, +0 or +5 mmHg relative to resting using dynamic end‐tidal forcing. Trials were performed in a quasi‐randomized, single‐blind manner. EMG DIA was assessed using an intraoesophageal catheter, standard ventilatory and gas exchange variables were collected, and the perception of dyspnoea intensity was assessed using the Borg category‐ratio 0–10 scale. EMG DIA increased significantly with ( P < 0.001) but was unaffected by changes in ( P = 0.320). Moreover, EMG DIA was significantly associated with , the work of breathing, and the pressure–time product of the diaphragm ( R 2 = 0.762–0.824; all P < 0.001), but not ( R 2 = 0.529; P = 0.947). Dyspnoea perception increased significantly with ( P < 0.001) and ( P < 0.001). During voluntary hyperpnoea involving manipulations of across a physiological range observed with exercise (i.e., 5 mmHg below and above resting ), EMG DIA reflects the mechanical ventilatory output of IND rather than changes in the drive to breathe due to variations in .

Experimental Physiology
University of Calgary (CA), University of Manitoba (CA), The University of Winnipeg (CA)
Neuroscience of respiration and sleep
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon