Comparing thermal and railway-induced effects in long-span road–rail truss bridges: The Tsing Ma bridge case study

Long-span road–rail suspension bridges with two-level steel truss decks require substantial depth and width to satisfy railway stiffness and serviceability demands, but these features also increase their sensitivity to non-uniform temperature fields across the deck cross-section. This study compares thermal and railway-induced effects on the Tsing Ma Bridge using a detailed three-dimensional finite element model validated against dead load, main-cable tension, and measured natural frequencies. Starting from the tensioned dead-load configuration, uniform, vertical, and transverse thermal components are applied independently together with two railway load cases, the measured service train and HSLM-A2. The uniform and vertical thermal inputs are derived from long-term monitoring of the Tsing Ma Bridge, while the transverse field is taken from a comparable road–rail truss bridge. The results show that thermal effects can be comparable to, or exceed, railway-induced effects depending on the response quantity considered. At the mid-span chords, the vertical and transverse thermal gradients reach 1.28 and 0.94 times the measured train effects, respectively, and 0.86 and 0.64 times the HSLM-A2 effects. Seasonal uniform temperature changes produce cable-force variations comparable to, or greater than, those caused by the service train. Among the thermal components considered, vertical gradients govern chord stresses, uniform temperature changes dominate cable-force variations and global deck deformation, and transverse gradients primarily affect the outer chords. A comparison with international design provisions further shows substantial differences in the representation of transverse thermal actions. These findings show that thermal loading can be comparable to, or exceed, railway service loading for specific response quantities in long-span road–rail truss bridges.

Authors

Institutions

Publication Details

Journal
Structures
Published
2026-11-21
DOI
https://doi.org/10.1016/j.istruc.2026.113595
Primary Topic
Structural Engineering and Materials Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Comparing thermal and railway-induced effects in long-span road–rail truss bridges: The Tsing Ma bridge case study

Marco Domaneschi, Joan Ramon Casas, Leonardo Zunino, Marco Manfrino
Structures
Structural Engineering and Materials Analysis
article

Comparing thermal and railway-induced effects in long-span road–rail truss bridges: The Tsing Ma bridge case study

Marco Domaneschi, Joan Ramon Casas, Leonardo Zunino, Marco Manfrino
article en

Abstract

Long-span road–rail suspension bridges with two-level steel truss decks require substantial depth and width to satisfy railway stiffness and serviceability demands, but these features also increase their sensitivity to non-uniform temperature fields across the deck cross-section. This study compares thermal and railway-induced effects on the Tsing Ma Bridge using a detailed three-dimensional finite element model validated against dead load, main-cable tension, and measured natural frequencies. Starting from the tensioned dead-load configuration, uniform, vertical, and transverse thermal components are applied independently together with two railway load cases, the measured service train and HSLM-A2. The uniform and vertical thermal inputs are derived from long-term monitoring of the Tsing Ma Bridge, while the transverse field is taken from a comparable road–rail truss bridge. The results show that thermal effects can be comparable to, or exceed, railway-induced effects depending on the response quantity considered. At the mid-span chords, the vertical and transverse thermal gradients reach 1.28 and 0.94 times the measured train effects, respectively, and 0.86 and 0.64 times the HSLM-A2 effects. Seasonal uniform temperature changes produce cable-force variations comparable to, or greater than, those caused by the service train. Among the thermal components considered, vertical gradients govern chord stresses, uniform temperature changes dominate cable-force variations and global deck deformation, and transverse gradients primarily affect the outer chords. A comparison with international design provisions further shows substantial differences in the representation of transverse thermal actions. These findings show that thermal loading can be comparable to, or exceed, railway service loading for specific response quantities in long-span road–rail truss bridges.

StructuresVol. 94
Politecnico di Torino (IT), Southeast University (CN), Universitat Politècnica de Catalunya (ES)
Structural Engineering and Materials Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon