A torsion-balance upper bound on the smearing length of least-decoherence hybrid gravity, and the decoherence floor it implies

In the Tilloy–Diósi model of Newtonian hybrid gravity selected by the principle of least decoherence, a single smearing length R0 does two things: it softens Newton's law below R0, and it sets the Diósi–Penrose decoherence rate, which decreases as R0 grows. We use the published final data of the 2020 Eöt-Wash test of the inverse-square law (Lee et al.), with its sign-resolved limits, and find for Gaussian smearing R0 ≲ 33 µm (observed one-sided 95 % limit from a profile likelihood; the honest band is 30–38 µm, so only the first figure is reliable), against an expected sensitivity of 38 µm. The compact least-heating profile gives almost the same edge, while a heavy-tailed profile gives a much tighter one in its scale parameter, which for that profile is not a width, and a higher floor. The upper edge alone implies a minimum decoherence rate for any mass in spatial superposition. For 10⁻¹⁴ kg split over 250 µm, the parameters of the Bose–Marletto–Vedral (BMV) proposal, and for each of the three smearing shapes considered, the observed limit gives about 0.75 s⁻¹ with the base fit and not less than about 0.6 s⁻¹ in any defensible variant of the fit; the expected sensitivity gives the same 0.6. Section 4.1 extends the calculation to all non-negative spherical smearings, under conditions stated there. The floor is there for a single particle, scales as m², and must come from the same R0 that a torsion balance would see. For Gaussian smearing, in the collinear BMV geometry the model produces no entanglement. We state what distinguishes this prediction from other models, and what does not. Version 12.3 (21 November 2026). Calculations and drafting were done with the help of an AI assistant (Claude, Anthropic); see the section "AI assistance and checks" of the note. Not peer reviewed. The 95 torque measurements used are those of J. G. Lee's PhD thesis (University of Washington, 2020), appendix A.1; they are not redistributed here, and the script package explains where to find them.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-21
DOI
https://doi.org/10.5281/zenodo.24414150
Primary Topic
Quantum Mechanics and Applications
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

A torsion-balance upper bound on the smearing length of least-decoherence hybrid gravity, and the decoherence floor it implies

Mario Caponi
Zenodo (CERN European Organization for Nuclear Research)
Quantum Mechanics and Applications
preprint

A torsion-balance upper bound on the smearing length of least-decoherence hybrid gravity, and the decoherence floor it implies

Mario Caponi
preprint en

Abstract

In the Tilloy–Diósi model of Newtonian hybrid gravity selected by the principle of least decoherence, a single smearing length R0 does two things: it softens Newton's law below R0, and it sets the Diósi–Penrose decoherence rate, which decreases as R0 grows. We use the published final data of the 2020 Eöt-Wash test of the inverse-square law (Lee et al.), with its sign-resolved limits, and find for Gaussian smearing R0 ≲ 33 µm (observed one-sided 95 % limit from a profile likelihood; the honest band is 30–38 µm, so only the first figure is reliable), against an expected sensitivity of 38 µm. The compact least-heating profile gives almost the same edge, while a heavy-tailed profile gives a much tighter one in its scale parameter, which for that profile is not a width, and a higher floor. The upper edge alone implies a minimum decoherence rate for any mass in spatial superposition. For 10⁻¹⁴ kg split over 250 µm, the parameters of the Bose–Marletto–Vedral (BMV) proposal, and for each of the three smearing shapes considered, the observed limit gives about 0.75 s⁻¹ with the base fit and not less than about 0.6 s⁻¹ in any defensible variant of the fit; the expected sensitivity gives the same 0.6. Section 4.1 extends the calculation to all non-negative spherical smearings, under conditions stated there. The floor is there for a single particle, scales as m², and must come from the same R0 that a torsion balance would see. For Gaussian smearing, in the collinear BMV geometry the model produces no entanglement. We state what distinguishes this prediction from other models, and what does not. Version 12.3 (21 November 2026). Calculations and drafting were done with the help of an AI assistant (Claude, Anthropic); see the section "AI assistance and checks" of the note. Not peer reviewed. The 95 torque measurements used are those of J. G. Lee's PhD thesis (University of Washington, 2020), appendix A.1; they are not redistributed here, and the script package explains where to find them.

Zenodo (CERN European Organization for Nuclear Research)
Quantum Mechanics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
A torsion-balance upper bound on the smearing length of least-decoherence hybrid gravity, and the decoherence floor it implies — Mario Caponi · Zenodo (CERN European Organization for Nuclear Research) (2026) | TGRS Research Map | TGRS