Effect of posterior longitudinal ligament resection on biomechanical characteristics in cervical disc arthroplasty: a finite element analysis

The posterior longitudinal ligament (PLL) plays a critical role in maintaining the biomechanical integrity. However, the biomechanical impact of PLL resection on the cervical spine remains a subject of debate. This study aimed to use finite element analysis (FEA) to determine the effects of PLL resection versus preservation on the biomechanics after cervical disc arthroplasty (CDA). A validated finite element model of the cervical spine (C3-C7) was developed based on computed tomography data from a patient with mild degenerative changes at C5-C6. At this level, a CDA model was constructed and implanted with three cervical disc prostheses (Bryan, Mobi-C, and Prodisc-C). For each prosthesis, both PLL-preserved and PLL-resected surgical models were established. Two distinct mechanical loading protocols were applied, namely identical axial preload with 1.0 Nm moment and displacement loading. The analyzed parameters encompassed range of motion (ROM), intervertebral disc stress (IDS), facet joint stress (FJS), bone-implant interface stress (BIS), prosthesis stress (PS). Compared with the preoperative condition, ROM increased at the operative segment (C5-C6) following all three disc replacements, indicating increased segmental ROM. Regarding the comparison between PLL resection and preservation, the majority of biomechanical parameters remained largely unchanged. However, a few notable exceptions were observed. Among them, the Bryan artificial disc exhibited the most pronounced change, with a 10.08% reduction in BIS during extension following PLL resection. The Prodisc-C demonstrated the greatest variation at the operative segment (C5-C6), where PS increased by 6.77% during extension while BIS decreased by approximately 3.5% during lateral bending, while changes during flexion (− 0.41%) and rotation (− 0.16%) were negligible. Aside from these isolated instances, all other parameter changes between PLL resection and preservation were minimal, generally remaining below 1%. Under the simulated quasi-static loading conditions, resection of the PLL during CDA did not meaningfully alter postoperative biomechanical outcomes. ROM at the operative segment was consistently increased regardless of the prosthesis type or PLL management strategy, and the few parameter variations observed between resection and preservation were minor under the simulated conditions. These findings suggest that biomechanical considerations alone need not drive the decision to resect the PLL; rather, the decision should be individualized based on the need for adequate decompression and patient-specific pathology.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-21
DOI
https://doi.org/10.1038/s41598-026-81146-0
Primary Topic
Cervical and Thoracic Myelopathy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Effect of posterior longitudinal ligament resection on biomechanical characteristics in cervical disc arthroplasty: a finite element analysis

Feifei Zhou, Hongpeng Sang, Cheng-Fei Du, Dacheng Sang et al.
Scientific Reports
Cervical and Thoracic Myelopathy
article

Effect of posterior longitudinal ligament resection on biomechanical characteristics in cervical disc arthroplasty: a finite element analysis

Feifei Zhou, Hongpeng Sang, Cheng-Fei Du, Dacheng Sang, Wenjie Ren, Hao Wu, Kuan Lu, Guanxiang Ding
article en

Abstract

The posterior longitudinal ligament (PLL) plays a critical role in maintaining the biomechanical integrity. However, the biomechanical impact of PLL resection on the cervical spine remains a subject of debate. This study aimed to use finite element analysis (FEA) to determine the effects of PLL resection versus preservation on the biomechanics after cervical disc arthroplasty (CDA). A validated finite element model of the cervical spine (C3-C7) was developed based on computed tomography data from a patient with mild degenerative changes at C5-C6. At this level, a CDA model was constructed and implanted with three cervical disc prostheses (Bryan, Mobi-C, and Prodisc-C). For each prosthesis, both PLL-preserved and PLL-resected surgical models were established. Two distinct mechanical loading protocols were applied, namely identical axial preload with 1.0 Nm moment and displacement loading. The analyzed parameters encompassed range of motion (ROM), intervertebral disc stress (IDS), facet joint stress (FJS), bone-implant interface stress (BIS), prosthesis stress (PS). Compared with the preoperative condition, ROM increased at the operative segment (C5-C6) following all three disc replacements, indicating increased segmental ROM. Regarding the comparison between PLL resection and preservation, the majority of biomechanical parameters remained largely unchanged. However, a few notable exceptions were observed. Among them, the Bryan artificial disc exhibited the most pronounced change, with a 10.08% reduction in BIS during extension following PLL resection. The Prodisc-C demonstrated the greatest variation at the operative segment (C5-C6), where PS increased by 6.77% during extension while BIS decreased by approximately 3.5% during lateral bending, while changes during flexion (− 0.41%) and rotation (− 0.16%) were negligible. Aside from these isolated instances, all other parameter changes between PLL resection and preservation were minimal, generally remaining below 1%. Under the simulated quasi-static loading conditions, resection of the PLL during CDA did not meaningfully alter postoperative biomechanical outcomes. ROM at the operative segment was consistently increased regardless of the prosthesis type or PLL management strategy, and the few parameter variations observed between resection and preservation were minor under the simulated conditions. These findings suggest that biomechanical considerations alone need not drive the decision to resect the PLL; rather, the decision should be individualized based on the need for adequate decompression and patient-specific pathology.

Scientific Reports
Tianjin University of Technology and Education (CN), Tianjin University of Technology (CN), Chifeng University (CN), Peking University (CN), Inner Mongolia University of Science and Technology (CN), Second Affiliated Hospital of Inner Mongolia Medical University (CN), Peking University Third Hospital (CN), Baotou Medical College (CN)
Cervical and Thoracic Myelopathy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon