Analysis Of Desalinated Water Contaminated with Ammonium Ions and Investigation of Possible Purification Methods Using Zeolite 4A
Process water in natural gas liquefaction plants are produced from seawater desalination units. To prevent corrosion of industrial equipments (pumps, heat exchangers, and boilers), process water must be treated appropriately. In this study, we determined the concentrations of ammonium and chloride ions in the process water from seawater desalination plant located in Arzew (western Algeria). Preliminary results show that concentrations of ammonium ions in desalinated water are quite high, reaching 2.0 ppm, which is a drawback not only for the quality of the desalinated water produced, but also for the longevity of industrial cooling equipment. A continuous adsorption study was conducted to remove ammonium ions from desalinated water using a fixed-bed column. Zeolite 4A that had already been used as a molecular sieve in natural gas dehydration was recovered for reuse as an adsorbent after chemical activation. The experiments were conducted at different bed heights (Z1 = 5 cm and Z2 = 7.5 cm) and ammonium ions concentration of 2.0 mg/L. Bohart-Adams model was applied to analyze the breakthrough curves at different conditions. The results of this study show that the maximum adsorption capacity increased from 87.25 mg/L to 91.59 mg/L when the bed height was increased from 5 to 7.5 cm. Key Words: Adsorption, Break through curves, Boharts-Adams model, Ammonium ions, Zeolite 4A.
Authors
- Malika Khelladi
- Driouch Aouatef
- Debab Abdelkader
- Mezouagh Amina
- Fares Zineb
- Mohamed Seghir Zahira
Institutions
- Université Oran 1 Ahmed Ben Bella (DZ)
- Université de Mostaganem (DZ)
- Université des Sciences et de la Technologie d'Oran Mohamed Boudiaf (DZ)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-21
- DOI
- https://doi.org/10.5281/zenodo.24415707
- Primary Topic
- Adsorption and biosorption for pollutant removal
- Type
- article
- Field-Weighted Citation Impact
- 0.00