Nonlinear radiative heat transference in a T-shaped porous fin saturated with GO–MoS 2 /H 2 O hybrid nanofluid: effects of temperature-dependent thermal conductivity and humidity-ratio linearization
In this work, a computational and machine-learning-based thermal investigation of a one-dimensional, fully wetted T-shaped porous fin operating under steady-state conditions is performed. The pores are saturated with a Graphene Oxide–Molybdenum Disulfide/Water (GO–MoS 2 /H 2 O) hybrid nanofluid that seeps through the matrix according to Darcy’s law, while a liquid film on the lateral surfaces evaporates into the ambient humid air. The energy equations of the stem and the flange include temperature-dependent matrix conductivity, convective–evaporative transfer through the Chilton–Colburn analogy with a linearised humidity-ratio closure, and untruncated fourth-power surface radiation expressed through the temperature-difference ratio θ r = T b − T a T a ${\theta }_{r}=\frac{\left({T}_{b}-{T}_{a}\right)}{{T}_{a}}$ . The coupled boundary value problem is solved with MATLAB bvp4c and verified against published limiting-case results with maximum deviation 2.08 %, against an independent quadrature solution obtained from the exact first integral deviations below 2 × 10 −8 , and through junction heat-rate and global energy-closure checks. Within the same solver, Taylor linearisation of the radiation term overestimates the junction temperature by up to 12 % and the fin efficiency by up to 20 % for θ r ≤ 0.4. The fin efficiency is defined as the ratio of consistently defined actual and ideal heat rates, and a maximum-principle argument shows that it lies between zero and unity. Variance-based sensitivity analysis of the exact model identifies the stem thickness-to-length ratio with total index 0.59 and the flange-to-stem length ratio value 0.22 as the dominant controls of the efficiency. An 8-10-6-1 Levenberg–Marquardt neural network surrogate trained on 200 Latin-hypercube samples reaches a coefficient of determination of 0.991 ± 0.010 on an independent 1,000-point test set over 10 repeated data splits, and it is reliable only inside its training domain.
Authors
- Paban Dhar
- Gurram Dharmaiah (ORCID: https://orcid.org/0000-0001-7788-5773)
- Kallur Venkat Nagaraja (ORCID: https://orcid.org/0000-0002-2190-5015)
- Bamdeb Dey (ORCID: https://orcid.org/0000-0002-9002-676X)
- Seepana Praveenkumar (ORCID: https://orcid.org/0000-0002-5667-9476)
Institutions
- Assam Don Bosco University (IN)
- Ural Federal University (RU)
- Karimganj College (IN)
- Amrita Vishwa Vidyapeetham (IN)
Publication Details
- Journal
- Chemical Product and Process Modeling
- Published
- 2026-11-23
- DOI
- https://doi.org/10.1515/cppm-2026-0264
- Primary Topic
- Heat Transfer and Numerical Methods
- Type
- article
- Field-Weighted Citation Impact
- 0.00