Development of a fully AI-based three-dimensional workflow for personalized target set-ups in orthodontics: First results

Introduction To present a fully automated artificial intelligence (AI) workflow to generate personalized orthodontic target set-ups and compare the quality of the occlusal outcome with manual set-ups, using the American Board of Orthodontics Model Grading System (ABO MGS). Material and methods The AI workflow takes an intraoral scan and performs tooth segmentation, landmark detection, tooth completion, and tooth alignment to generate a 3D-printable personalized set-up without human intervention. The occlusal outcome was evaluated on twenty non-extraction full jaw cases treated with customized fixed appliances by comparing the AI set-ups to manual set-ups made by experienced laboratory technicians. Both set-up series were scored with the ABO MGS for alignment and rotations, marginal ridges, buccolingual inclination, overjet, occlusal contacts, occlusal relationships, and interproximal contacts. The ‘alignment and rotations’ category was additionally analysed separately for the anterior (canine to canine) and posterior (premolars to second molars) segments. Paired comparisons used the two-sided Wilcoxon signed-rank test (α = 0.05). Results Based on the total ABO MGS scores, the AI set-ups (mean: 14.95) and manual set-ups (mean: 12.20) showed high-quality occlusal outcomes, which were both far below the ABO passing score. AI set-ups showed significantly more penalty points for alignment and rotations (median: 8 vs. 5; P < 0.001). This difference was confined to the posterior segments; anterior alignment was near-ideal for both methods. Other categories did not differ significantly ( P = 0.082–0.886). Conclusions For the first time, a fully automated AI-based 3D workflow generated personalized orthodontic target set-ups for non-extraction cases with a clinically acceptable, high-quality occlusal outcome, in approximately four minutes. Posterior alignment remains the only shortcoming of the AI set-ups and is the obvious target for further algorithm refinement or brief manual correction.

Authors

Institutions

Publication Details

Journal
International Orthodontics
Published
2026-11-21
DOI
https://doi.org/10.1016/j.ortho.2026.101269
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Development of a fully AI-based three-dimensional workflow for personalized target set-ups in orthodontics: First results

Dirk Wiechmann, Niels van Nistelrooij, Shankeeth Vinayahalingam
International Orthodontics
Orthodontics and Dentofacial Orthopedics
article

Development of a fully AI-based three-dimensional workflow for personalized target set-ups in orthodontics: First results

Dirk Wiechmann, Niels van Nistelrooij, Shankeeth Vinayahalingam
article en

Abstract

Introduction To present a fully automated artificial intelligence (AI) workflow to generate personalized orthodontic target set-ups and compare the quality of the occlusal outcome with manual set-ups, using the American Board of Orthodontics Model Grading System (ABO MGS). Material and methods The AI workflow takes an intraoral scan and performs tooth segmentation, landmark detection, tooth completion, and tooth alignment to generate a 3D-printable personalized set-up without human intervention. The occlusal outcome was evaluated on twenty non-extraction full jaw cases treated with customized fixed appliances by comparing the AI set-ups to manual set-ups made by experienced laboratory technicians. Both set-up series were scored with the ABO MGS for alignment and rotations, marginal ridges, buccolingual inclination, overjet, occlusal contacts, occlusal relationships, and interproximal contacts. The ‘alignment and rotations’ category was additionally analysed separately for the anterior (canine to canine) and posterior (premolars to second molars) segments. Paired comparisons used the two-sided Wilcoxon signed-rank test (α = 0.05). Results Based on the total ABO MGS scores, the AI set-ups (mean: 14.95) and manual set-ups (mean: 12.20) showed high-quality occlusal outcomes, which were both far below the ABO passing score. AI set-ups showed significantly more penalty points for alignment and rotations (median: 8 vs. 5; P < 0.001). This difference was confined to the posterior segments; anterior alignment was near-ideal for both methods. Other categories did not differ significantly ( P = 0.082–0.886). Conclusions For the first time, a fully automated AI-based 3D workflow generated personalized orthodontic target set-ups for non-extraction cases with a clinically acceptable, high-quality occlusal outcome, in approximately four minutes. Posterior alignment remains the only shortcoming of the AI set-ups and is the obvious target for further algorithm refinement or brief manual correction.

International OrthodonticsVol. 25(1)
University of Bern (CH), Radboud University Nijmegen (NL), Radboud University Medical Center (NL), Medizinische Hochschule Hannover (DE)
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon