Patient-specific 3D-printed partial femoral head replacement for peri-collapse osteonecrosis of the femoral head: a prospective observational study of early clinical outcomes
Hip preservation in patients with peri-collapse osteonecrosis of the femoral head (ONFH) remains challenging, particularly when structural support and articular congruity of the femoral head have been compromised. Conventional hip-preserving procedures may be insufficient to restore the structural integrity of the affected femoral head. We developed a patient-specific 3D-printed partial femoral head arthroplasty to enable lesion-specific resection and individualized reconstruction while preserving viable native bone and the acetabulum. This study aimed to evaluate the early clinical and radiographic outcomes of this approach in carefully selected patients with peri-collapse ONFH. This prospective observational study included 31 consecutive patients with symptomatic peri-collapse ONFH who underwent patient-specific 3D-printed partial femoral head arthroplasty between November 2022 and June 2025. Preoperative computed tomography was used for three-dimensional reconstruction and patient-specific prosthesis and surgical guide design. Clinical outcomes were assessed using the visual analogue scale (VAS), Harris Hip Score (HHS), range of motion (ROM), Oxford Hip Score (OHS), and EQ-VAS. Postoperative radiographs were evaluated for prosthetic position, acetabular changes, and radiographic complications, while postoperative complications and revision surgery were recorded during follow-up. The mean follow-up duration was 24.5 ± 8.0 months. Significant improvements were observed in pain, hip function, and range of motion at the latest follow-up. The mean VAS score decreased from 7.3 ± 0.7 preoperatively to 2.4 ± 1.7, while the mean HHS increased from 51.3 ± 6.6 to 87.2 ± 10.2 (both P < 0.001). At the latest follow-up, the mean OHS was 41.1 ± 3.1 and the mean EQ-5D-5 L visual analogue scale score was 79.7 ± 10.6. Twenty-seven patients (87.1%) reported being very or moderately satisfied with the procedure. Two patients underwent revision to THA and three additional patients reported residual pain; other findings included heterotopic ossification, suspected acetabular osteoarthritis progression, and one incisional infection requiring debridement, with no PJI, dislocation, aseptic loosening, or periprosthetic fracture. Patient-specific 3D-printed partial femoral head replacement is a feasible hip-preserving approach for carefully selected patients with peri-collapse ONFH. By combining lesion-specific resection with individualized structural and articular surface reconstruction, this technique was associated with substantial improvements in pain and hip function while preserving native bone and the acetabulum. Longer-term follow-up and comparative studies are warranted to determine the durability and clinical role of this approach. Chinese Clinical Trial Registry, ChiCTR2300073131; Date of registration: 3 July 2023, Retrospectively registered.
Authors
- Jiaxiang Gao (ORCID: https://orcid.org/0000-0002-5924-200X)
- Wei Wang (ORCID: https://orcid.org/0000-0003-1005-059X)
- Ran Ding (ORCID: https://orcid.org/0000-0002-7453-8968)
- Cheng Huang (ORCID: https://orcid.org/0000-0002-8793-5946)
- Yue Peng
- Fengrui Liu
- Yaxing Duan
- Tong Li
- Qidong Zhang
- Zhaohui Liu
Institutions
- Chinese Academy of Medical Sciences & Peking Union Medical College (CN)
- Peking University (CN)
- China-Japan Friendship Hospital (CN)
- Peking Union Medical College Hospital (CN)
Publication Details
- Journal
- Journal of Orthopaedic Surgery and Research
- Published
- 2026-11-21
- DOI
- https://doi.org/10.1186/s13018-026-07392-0
- Primary Topic
- Orthopaedic implants and arthroplasty
- Type
- article
- Field-Weighted Citation Impact
- 0.00