Transient multi-phase flow and pressure-response characteristics in a high-speed arc–involute–arc composite helical gear pump

This study integrates analytical modeling, transient multi-phase computational fluid dynamics (CFD), and experiments to investigate the delivery and pressure-response characteristics of a high-speed arc–involute–arc composite helical gear pump. A coordinate- and tangent-continuous tooth profile and an analytical instantaneous-flow model incorporating axial phase differences provide a geometric displacement reference. A three-dimensional transient multi-phase CFD model is established in Simerics-MP+ using oil properties prescribed at 318 K. The combined approach assesses departures from geometric flow predictions. As rotational speed increases from 4000 to 5500 r/min, the CFD-predicted flow pulsation rate increases from 26.48% to 36.98%, while volumetric efficiency decreases from 95.17% to 91.10%. Numerical flow fields associate these changes with insufficient suction filling, clearance reverse flow, and local gas–vapor evolution. At 5000 r/min, increasing load pressure from 0.5 to 6.5 MPa reduces the predicted relative pressure pulsation rate from 12.96% to 1.65%. However, the absolute peak-to-peak pressure fluctuation remains within 0.065–0.110 MPa, indicating that the relative reduction primarily reflects increasing mean pressure. Experiments reproduce the speed- and load-dependent trends, with the maximum relative volumetric-efficiency deviations of 3.94% and 2.53%, respectively. The maximum relative deviation in the flow pulsation rate is 6.83% at 5000 r/min. Relative pressure pulsation is consistently underpredicted by 0.85–2.56 percentage points. These findings provide a geometry-specific basis for evaluating delivery efficiency and pulsation.

Authors

Institutions

Publication Details

Journal
Proceedings of the Institution of Mechanical Engineers Part E Journal of Process Mechanical Engineering
Published
2026-11-21
DOI
https://doi.org/10.1177/09544089261509315
Primary Topic
Gear and Bearing Dynamics Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Transient multi-phase flow and pressure-response characteristics in a high-speed arc–involute–arc composite helical gear pump

梁俊, Wei Liu, Xuehui Chen, Lizhi Jiang et al.
Proceedings of the Institution of Mechanical Engineers Part E Journal of Process Mechanical Engineering
Gear and Bearing Dynamics Analysis
article

Transient multi-phase flow and pressure-response characteristics in a high-speed arc–involute–arc composite helical gear pump

梁俊, Wei Liu, Xuehui Chen, Lizhi Jiang, Ting Gao, Junpeng Zhang, Tao Ma, Hao Li, Hewang Ma
article en

Abstract

This study integrates analytical modeling, transient multi-phase computational fluid dynamics (CFD), and experiments to investigate the delivery and pressure-response characteristics of a high-speed arc–involute–arc composite helical gear pump. A coordinate- and tangent-continuous tooth profile and an analytical instantaneous-flow model incorporating axial phase differences provide a geometric displacement reference. A three-dimensional transient multi-phase CFD model is established in Simerics-MP+ using oil properties prescribed at 318 K. The combined approach assesses departures from geometric flow predictions. As rotational speed increases from 4000 to 5500 r/min, the CFD-predicted flow pulsation rate increases from 26.48% to 36.98%, while volumetric efficiency decreases from 95.17% to 91.10%. Numerical flow fields associate these changes with insufficient suction filling, clearance reverse flow, and local gas–vapor evolution. At 5000 r/min, increasing load pressure from 0.5 to 6.5 MPa reduces the predicted relative pressure pulsation rate from 12.96% to 1.65%. However, the absolute peak-to-peak pressure fluctuation remains within 0.065–0.110 MPa, indicating that the relative reduction primarily reflects increasing mean pressure. Experiments reproduce the speed- and load-dependent trends, with the maximum relative volumetric-efficiency deviations of 3.94% and 2.53%, respectively. The maximum relative deviation in the flow pulsation rate is 6.83% at 5000 r/min. Relative pressure pulsation is consistently underpredicted by 0.85–2.56 percentage points. These findings provide a geometry-specific basis for evaluating delivery efficiency and pulsation.

Proceedings of the Institution of Mechanical Engineers Part E Journal of Process Mechanical Engineering
Anhui Jianzhu University (CN), Hefei University of Technology (CN), Hefei University (CN)
Gear and Bearing Dynamics Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon