A stability indicating RP-HPLC method development and validation for the determination of gepotidacin in bulk drug and pharmaceutical dosage form as per ICH guidelines

A simple, Précised, Accurate method was developed for the estimation of Gepotidacin by RP-HPLC technique. Chromatographic conditions used are stationary phase Agilent C18 250mm x 4.6 mm, 5m ,Mobile phase 0.01N Kh2po4: Acetonitrile in the ratio of 60:40 and flow rate was maintained at 1.0ml/min, detection wave length was 288nm, column temperature was set to 30oC and diluent was mobile phase Conditions were finalized as optimized method. System suitability parameters were studied by injecting the standard six times and results were well under the acceptance criteria. Linearity study was carried out between 25% to150 % levels, R2 value was found to be as 0.999. Precision was found to be 0.5 for repeatability and 0.8 for intermediate precision. LOD and LOQ are 0.13µg/ml and 0.40µg/ml respectively

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-21
DOI
https://doi.org/10.5281/zenodo.24413277
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A stability indicating RP-HPLC method development and validation for the determination of gepotidacin in bulk drug and pharmaceutical dosage form as per ICH guidelines

Panneeru Akshaya
Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

A stability indicating RP-HPLC method development and validation for the determination of gepotidacin in bulk drug and pharmaceutical dosage form as per ICH guidelines

Panneeru Akshaya
article en

Abstract

A simple, Précised, Accurate method was developed for the estimation of Gepotidacin by RP-HPLC technique. Chromatographic conditions used are stationary phase Agilent C18 250mm x 4.6 mm, 5m ,Mobile phase 0.01N Kh2po4: Acetonitrile in the ratio of 60:40 and flow rate was maintained at 1.0ml/min, detection wave length was 288nm, column temperature was set to 30oC and diluent was mobile phase Conditions were finalized as optimized method. System suitability parameters were studied by injecting the standard six times and results were well under the acceptance criteria. Linearity study was carried out between 25% to150 % levels, R2 value was found to be as 0.999. Precision was found to be 0.5 for repeatability and 0.8 for intermediate precision. LOD and LOQ are 0.13µg/ml and 0.40µg/ml respectively

Zenodo (CERN European Organization for Nuclear Research)
Jawaharlal Nehru Technological University, Hyderabad (IN)
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon