Delivery time and wastage of red blood cell units in a Swiss transfusion network: a 5-year retrospective study: RBC delivery time

Background - Efficient distribution of red blood cell concentrates (RCCs) is essential for maintaining product quality and minimizing wastage. This study examined RCC distribution across three Swiss cantons and temporal patterns across the COVID-19 period. Materials and methods - A retrospective analysis of Interregional Blood Transfusion SRC (Swiss Red Cross) data was conducted on RCCs distributed to hospitals in Vaud, Valais and Bern between 2019 and 2023. Delivery time was defined as the time between donation and the recorded delivery event at a clinical or laboratory recipient, and wastage as recorded discard-coded records. Analyses examined delivery time by destination region, recipient hospital type, ABO/Rh blood group, collection kits, product type and COVID-19 period. Results - A total of 312,340 records were included, comprising 295,544 clinical/laboratory deliveries and 10,364 recorded discards (3.3%). Mean delivery time was 15.4 days (median 15 days) and ranged from 13.3 to 17.3 days across canton and institution groups. Among standard products, the longer-shelf-life collection system had a longer mean delivery time (20.8 vs 14.7 days, p<0.001) and more deliveries after 35 days (3.3% vs 1.0%). Delivery after 35 days occurred in 12.5% of AB+ and 5.6% of AB− deliveries, compared with 0.5%-1.3% for A and O groups. Irradiated and washed RCCs had recorded discard proportions of 0.3% and 0%, respectively, whereas paediatric splits had a recorded discard proportion of 36.6%. Mean delivery times were 15.3, 14.5 and 16.0 days across the three predefined calendar COVID-19 periods; recorded discard proportions were 3.8%, 3.4% and 3.0%, respectively. Discussion - RCC delivery times remained within licensed storage limits, but disparities persisted across regions, recipient types and blood groups. Calendar-period differences did not establish a causal effect of the pandemic. These findings highlight opportunities to optimize inventory management and reduce wastage, particularly for least common blood groups.

Authors

Publication Details

Journal
Blood transfusion
Published
2026-11-20
DOI
https://doi.org/10.2450/bloodtransfus.1460
Primary Topic
Blood donation and transfusion practices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Delivery time and wastage of red blood cell units in a Swiss transfusion network: a 5-year retrospective study: RBC delivery time

Michel Prudent, Frédéric Gaspar, Dylan Duarte
Blood transfusion
Blood donation and transfusion practices
article

Delivery time and wastage of red blood cell units in a Swiss transfusion network: a 5-year retrospective study: RBC delivery time

Michel Prudent, Frédéric Gaspar, Dylan Duarte
article en

Abstract

Background - Efficient distribution of red blood cell concentrates (RCCs) is essential for maintaining product quality and minimizing wastage. This study examined RCC distribution across three Swiss cantons and temporal patterns across the COVID-19 period. Materials and methods - A retrospective analysis of Interregional Blood Transfusion SRC (Swiss Red Cross) data was conducted on RCCs distributed to hospitals in Vaud, Valais and Bern between 2019 and 2023. Delivery time was defined as the time between donation and the recorded delivery event at a clinical or laboratory recipient, and wastage as recorded discard-coded records. Analyses examined delivery time by destination region, recipient hospital type, ABO/Rh blood group, collection kits, product type and COVID-19 period. Results - A total of 312,340 records were included, comprising 295,544 clinical/laboratory deliveries and 10,364 recorded discards (3.3%). Mean delivery time was 15.4 days (median 15 days) and ranged from 13.3 to 17.3 days across canton and institution groups. Among standard products, the longer-shelf-life collection system had a longer mean delivery time (20.8 vs 14.7 days, p<0.001) and more deliveries after 35 days (3.3% vs 1.0%). Delivery after 35 days occurred in 12.5% of AB+ and 5.6% of AB− deliveries, compared with 0.5%-1.3% for A and O groups. Irradiated and washed RCCs had recorded discard proportions of 0.3% and 0%, respectively, whereas paediatric splits had a recorded discard proportion of 36.6%. Mean delivery times were 15.3, 14.5 and 16.0 days across the three predefined calendar COVID-19 periods; recorded discard proportions were 3.8%, 3.4% and 3.0%, respectively. Discussion - RCC delivery times remained within licensed storage limits, but disparities persisted across regions, recipient types and blood groups. Calendar-period differences did not establish a causal effect of the pandemic. These findings highlight opportunities to optimize inventory management and reduce wastage, particularly for least common blood groups.

Blood transfusion
Blood donation and transfusion practices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Delivery time and wastage of red blood cell units in a Swiss transfusion network: a 5-year retrospective study: RBC delivery time — Michel Prudent, Frédéric Gaspar, et al. · Blood transfusion (2026) | TGRS Research Map | TGRS