Adaptive sliding mode control for precise detection of weak battery impedance under strong electromagnetic interference
Electrochemical impedance spectroscopy (EIS) enables noninvasive battery-health assessment, but strong electromagnetic interference (EMI) degrades weak-signal current tracking. This study integrates a fixed-bandwidth linear extended state observer for disturbance estimation, projection-bounded adaptive-gain sliding-mode control with resonant compensation for sinusoidal tracking, and a switchable linear-phase equiripple finite-impulse-response filter bank with group-delay correction. The adaptive law updates the sliding-mode reaching gain, while a composite Lyapunov analysis establishes uniform ultimate boundedness. Experiments on battery cells and a 144 V pack over 0.1 Hz–10 kHz yield 1.2%–1.5% impedance error relative to a Zahner reference and 68.4%–83.7% accuracy improvements over proportional-integral-resonant control.
Authors
- Jisen Li (ORCID: https://orcid.org/0000-0002-7336-2809)
- Dongqi Zhao
- Xuemin Chen
- Ze Zhou
- Liyan Zhang
- Qihong Chen
Institutions
- Wuhan University of Technology (CN)
Publication Details
- Journal
- International Journal of Green Energy
- Published
- 2026-11-21
- DOI
- https://doi.org/10.1080/15435075.2026.2762098
- Primary Topic
- Battery Modeling and Management
- Type
- article
- Field-Weighted Citation Impact
- 0.00