Dynamical decoupling, not error detection, protects an idle quantum register on heavy-hex: a preregistered code-space Hayden-Preskill test on IBM Heron r2, and a validated design for Quantinuum H2

Preregistered (10.5281/zenodo.24425416) hardware test on ibm_marrakesh, 216 circuits, 63 QPU seconds. A [[4,2,2]]-encoded idle reference register (5-CNOT star encoder fitted to heavy-hex) did not improve Hayden-Preskill-style entanglement recovery; staggered native-gate XY4 dynamical decoupling raised two-pair Bell fidelity by 0.10-0.18 at a 20 microsecond idle window (4 of 4 DD tests supported, Holm alpha = 0.01). The simulator with IBM's published noise model predicted the opposite on both counts. Includes a full-encoding design for Quantinuum H2 (72 circuits, every H2-1-compiled circuit verified exactly), predictions under an H2-like noise model, and exact HQC costs: 1,336 HQC for the decisive comparison at 500 shots. Version 1.1: cites the trapped-ion precedents (Landsman et al. 2019, verified scrambling; Linke et al. 2017, fault-tolerant [[4,2,2]] error detection and the IBM/ion-trap architecture comparison; Pino et al. 2021; Gaebler et al. 2021) and notes that the H2 noise model omits mid-circuit-measurement crosstalk. Data and results are unchanged.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-20
DOI
https://doi.org/10.5281/zenodo.24425627
Primary Topic
Quantum Computing Algorithms and Architecture
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Dynamical decoupling, not error detection, protects an idle quantum register on heavy-hex: a preregistered code-space Hayden-Preskill test on IBM Heron r2, and a validated design for Quantinuum H2

Devin Phillip Davis
Zenodo (CERN European Organization for Nuclear Research)
Quantum Computing Algorithms and Architecture
preprint

Dynamical decoupling, not error detection, protects an idle quantum register on heavy-hex: a preregistered code-space Hayden-Preskill test on IBM Heron r2, and a validated design for Quantinuum H2

Devin Phillip Davis
preprint en

Abstract

Preregistered (10.5281/zenodo.24425416) hardware test on ibm_marrakesh, 216 circuits, 63 QPU seconds. A [[4,2,2]]-encoded idle reference register (5-CNOT star encoder fitted to heavy-hex) did not improve Hayden-Preskill-style entanglement recovery; staggered native-gate XY4 dynamical decoupling raised two-pair Bell fidelity by 0.10-0.18 at a 20 microsecond idle window (4 of 4 DD tests supported, Holm alpha = 0.01). The simulator with IBM's published noise model predicted the opposite on both counts. Includes a full-encoding design for Quantinuum H2 (72 circuits, every H2-1-compiled circuit verified exactly), predictions under an H2-like noise model, and exact HQC costs: 1,336 HQC for the decisive comparison at 500 shots. Version 1.1: cites the trapped-ion precedents (Landsman et al. 2019, verified scrambling; Linke et al. 2017, fault-tolerant [[4,2,2]] error detection and the IBM/ion-trap architecture comparison; Pino et al. 2021; Gaebler et al. 2021) and notes that the H2 noise model omits mid-circuit-measurement crosstalk. Data and results are unchanged.

Zenodo (CERN European Organization for Nuclear Research)
Quantum Computing Algorithms and Architecture
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Dynamical decoupling, not error detection, protects an idle quantum register on heavy-hex: a preregistered code-space Hayden-Preskill test on IBM Heron r2, and a validated design for Quantinuum H2 — Devin Phillip Davis · Zenodo (CERN European Organization for Nuclear Research) (2026) | TGRS Research Map | TGRS