Automatic Identification of Thunderstorm Charge Structure Using Physically Constrained DBSCAN Clustering

Accurate identification of thunderstorm charge structure is critical for advancing our understanding of thunderstorm electrification and discharge mechanisms, as well as enhancing lightning early warning capabilities. However, existing charge structure retrieval methods have notable limitations: manual analysis is labor‐intensive and inefficient, while existing automatic methods suffer from insufficient integration of physical constraints, making them susceptible to interference from polarity‐ambiguous regions, and highly prone to failure in scenarios involving atypical discharges or missing local signals, ultimately rendering them unsuitable for the retrieval demands of large‐scale lightning data. To overcome these limitations, this paper proposes an automatic charge structure identification method based on physically constrained DBSCAN clustering. Utilizing three‐dimensional (3D) very high frequency (VHF) radiation source location data, the method constructs an end‐to‐end automatic identification framework through four core steps: data quality control, physical constraint enforcement for polarity‐ambiguous regions, KD‐Tree spatial indexing optimization, and physically constrained DBSCAN density clustering. Validation using typical normal and inverted‐polarity intracloud (IC) flash cases demonstrates an overall identification accuracy exceeding 99%, with results highly consistent with physical observations such as leader propagation speeds. Furthermore, the successful identification of atypical quasi‐positive IC flashes further validates the method's robustness in scenarios involving biased detection data. When applied to a 10‐min continuous thunderstorm episode, the method successfully reconstructs the tripolar charge structure, characterized by an upper dominant positive, a middle dominant negative, and a lower secondary positive charge region. This method provides an accurate and efficient technical approach for extracting charge structure information from lightning location data.

Authors

Institutions

Publication Details

Journal
Journal of Geophysical Research Atmospheres
Published
2026-11-21
DOI
https://doi.org/10.1029/2026jd047272
Primary Topic
Lightning and Electromagnetic Phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Automatic Identification of Thunderstorm Charge Structure Using Physically Constrained DBSCAN Clustering

Shi Qiu, Lihua Shi, Zheng Sun, Yun Li et al.
Journal of Geophysical Research Atmospheres
Lightning and Electromagnetic Phenomena
article

Automatic Identification of Thunderstorm Charge Structure Using Physically Constrained DBSCAN Clustering

Shi Qiu, Lihua Shi, Zheng Sun, Yun Li, Shuangjiang Du, Yueyang Wang
article en

Abstract

Accurate identification of thunderstorm charge structure is critical for advancing our understanding of thunderstorm electrification and discharge mechanisms, as well as enhancing lightning early warning capabilities. However, existing charge structure retrieval methods have notable limitations: manual analysis is labor‐intensive and inefficient, while existing automatic methods suffer from insufficient integration of physical constraints, making them susceptible to interference from polarity‐ambiguous regions, and highly prone to failure in scenarios involving atypical discharges or missing local signals, ultimately rendering them unsuitable for the retrieval demands of large‐scale lightning data. To overcome these limitations, this paper proposes an automatic charge structure identification method based on physically constrained DBSCAN clustering. Utilizing three‐dimensional (3D) very high frequency (VHF) radiation source location data, the method constructs an end‐to‐end automatic identification framework through four core steps: data quality control, physical constraint enforcement for polarity‐ambiguous regions, KD‐Tree spatial indexing optimization, and physically constrained DBSCAN density clustering. Validation using typical normal and inverted‐polarity intracloud (IC) flash cases demonstrates an overall identification accuracy exceeding 99%, with results highly consistent with physical observations such as leader propagation speeds. Furthermore, the successful identification of atypical quasi‐positive IC flashes further validates the method's robustness in scenarios involving biased detection data. When applied to a 10‐min continuous thunderstorm episode, the method successfully reconstructs the tripolar charge structure, characterized by an upper dominant positive, a middle dominant negative, and a lower secondary positive charge region. This method provides an accurate and efficient technical approach for extracting charge structure information from lightning location data.

Journal of Geophysical Research AtmospheresVol. 131(22)
PLA Army Engineering University (CN)
Lightning and Electromagnetic Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon